Li Liang,Wang Li,Zeng Feifei,Liu Fang,Peng Zhoufeng,Xie Baojun,Liu Changsheng,Zha Yunfei.The application value of low-dose CT scan in pregnant women with COVID-19[J].Chinese Journal of Radiological Medicine and Protection,2020,40(5):333-337
The application value of low-dose CT scan in pregnant women with COVID-19
Received:March 01, 2020  
DOI:10.3760/cma.j.issn.0254-5098.2020.05.001
KeyWords:Radiation dose  Pregnancy  COVID-19  Tomography, X-ray computed
FundProject:
Author NameAffiliationE-mail
Li Liang Department of Radiology, Renmin Hospital of Wuhan University, Wuhan 430060, China  
Wang Li Department of Infection Prevention and Control, Renmin Hospital of Wuhan University, Wuhan 430060, China  
Zeng Feifei Department of Radiology, Renmin Hospital of Wuhan University, Wuhan 430060, China  
Liu Fang Department of Radiology, Renmin Hospital of Wuhan University, Wuhan 430060, China  
Peng Zhoufeng Department of Radiology, Renmin Hospital of Wuhan University, Wuhan 430060, China  
Xie Baojun Department of Radiology, Renmin Hospital of Wuhan University, Wuhan 430060, China  
Liu Changsheng Department of Radiology, Renmin Hospital of Wuhan University, Wuhan 430060, China  
Zha Yunfei Department of Radiology, Renmin Hospital of Wuhan University, Wuhan 430060, China zhayunfei999@126.com 
Hits: 2397
Download times: 969
Abstract::
      Objective To explore the value of low-dose CT in pregnancy with COVID-19. Methods A retrospective analysis was performed on the clinical characteristics, laboratory tests, and chest CT findings of 12 pregnant women with COVID-19 diagnosed by nucleic acid testing in the Renmin Hospital of Wuhan University from January 20, 2020 to February 16, 2020. Two radiologists blinded to the reconstruction algorithm independently scored subjective image quality on a 5-point Likert scale. Image quality score ≥ 3 was acceptable in clinics. The CT radiation doses were recorded, including CT volume dose index (CTDIvol), dose length product (DLP), and effective radiation dose (E). Two radiologists observed the distribution, shape, density, and other characteristics of lung lesions, and they also decided whether hilar, mediastinal lymphadenopathy, and pleural changed. Results A total of 12 pregnant women with COVID-19, 8 had cough, 4 had fever, 2 had chest tightness, and 1 had dyspnea and diarrhea each. The CT image quality score of all patients was 3-4, with an average of 3.46, which fully met the clinical diagnosis requirements. The CTDIvol value was 1.13-4.31 mGy, with an average of 3.02 mGy. The DLP value was 34.48-75.29 mGy·cm, with an average of 55.48 mGy·cm. The Evalue was 0.48-1.05 mSv, with an average of 0.78 mSv. In all cases, chest CT examination showed abnormal manifestations after clinical symptoms, including unilateral lung lesions in 5 cases and bilateral lung lesions in 7 cases, 1 case of ground-glass opacity, 1 case of solidification, 7 cases of ground-glass and consolidation, 1 case of strip opacity, ground-glass, and consolidation and strip cable shadow coexisted in 2 cases. Conclusions The application of low-dose CT scan in pregnant women with COVID-19 is completely feasible. CT mainly manifested as bilateral lung patchy and flaky ground-glass opacity with consolidation. Active and effective treatment can help recover and improve prognosis.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9058534  On-line:0

v
Scan QR Code
&et=93F632ED6E2662A6FCE07206EF7DDEE39DC73150B66C46CB9BAED5D482F5F52D787C8A2433994CFD607EBF375B835ECA880BA18A0C11C57AFB0415580BB38A245F2F77375FC509003E8896165ACB3352&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=0D1D160AB8016934&aid=D0890C20B2C0ACC31FFC6F9F591C5CC2&vid=&iid=94C357A881DFC066&sid=CF6CB42CFF3D4C4E&eid=5FF9F4F7CB1800C7&fileno=20200501&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="0D1D160AB8016934"; var my_aid="D0890C20B2C0ACC31FFC6F9F591C5CC2";