Xu Zhe,Song Bin,Zhang Yin,Sun Guoqing,Wei Zhaoyang,Yao Jianhua,Yang Yuexin.Study on public dose burden in Suzhou from medical exposure in X-ray digital radiography and computed tomography[J].Chinese Journal of Radiological Medicine and Protection,2019,39(12):940-945
Study on public dose burden in Suzhou from medical exposure in X-ray digital radiography and computed tomography
Received:July 29, 2019  
DOI:10.3760/cma.j.issn.0254-5098.2019.12.012
KeyWords:Digital radiography(DR)  Computed tomography(CT)  Medical exposure  Effective dose
FundProject:省部共建放射医学与防护国家重点实验室开放课题(GZK1201815)
Author NameAffiliationE-mail
Xu Zhe Department of Occupational and Radiological Health, Suzhou Municipal Center for Disease Prevention and Control, Suzhou 215004, China  
Song Bin Department of Occupational and Radiological Health, Suzhou Municipal Center for Disease Prevention and Control, Suzhou 215004, China hustsongbin@126.com 
Zhang Yin Department of Occupational and Radiological Health, Suzhou Municipal Center for Disease Prevention and Control, Suzhou 215004, China  
Sun Guoqing Department of Occupational and Radiological Health, Suzhou Municipal Center for Disease Prevention and Control, Suzhou 215004, China  
Wei Zhaoyang Department of Occupational and Radiological Health, Suzhou Municipal Center for Disease Prevention and Control, Suzhou 215004, China  
Yao Jianhua Department of Occupational and Radiological Health, Suzhou Municipal Center for Disease Prevention and Control, Suzhou 215004, China  
Yang Yuexin Department of Occupational and Radiological Health, Suzhou Municipal Center for Disease Prevention and Control, Suzhou 215004, China  
Hits: 2429
Download times: 1134
Abstract::
      Objective To estimate the effective dose burden to the public in Suzhoui induced by medical exposure from computed tomography (CT) and digital radiography (DR). Methods Twenty-seven hospitals were selected by stratified random sampling. The application information was colleted from picture archiving and communication system (PACS) and radiology information system (RIS). For DR, DAP was measured by the dose-area product meter in different body parts, then the effective dose values were calculated by the DAP. For CT, effective dose was estimated by measuring CT dose index weighted (CTDI\-w) and scanning parameters in different parts of the body. The public dose burden caused by DR and CT medical exposure in Suzhou was estimated according to the scanning time and effective dose to each part. Results The effective dose due to DR examination was abdomen AP 0.565 mSv, pelvis AP 0.280 mSv, skull LAT 0.016 mSv, skull AP 0.012 mSv, chest LAT 0.111 mSv, chest AP 0.060 mSv, thoracic spine LAT 0.100 mSv, thoracic spine AP 0.102 mSv, lumbar spine LAT 0.307 mSv and lumbar spine AP 0.152 mSv, respectively. The effective doses from CT scanning were 1.33 mSv for head, 5.75 mSv for thorax and 7.31 mSv for abdomen, respectively. The annual collective effective dose in Suzhou in 2017 from DR exposures and CT scans was 9 593.07 man·Sv, and the average annual effective dose was 0.898 mSv. Conclusions The contribution of CT medical radiation to the public dose is much greater than that of DR. Controlling the frequency of medical exposure and single scan dose is an effective way to reduce the public dose burden. The public dose burden from DR and CT medical exposure in Suzhou is at a high level and attention needs to be paid by relevant health administrative departments.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9076147  On-line:0

v
Scan QR Code
&et=08EE5A5866ACE440D1AC788551978013F3D386DEE32DA156F47BE2FD846AAD534619FE583F4D11C1F8FAAFF6236CC1747453CDA39FAC3713879E71B4CE599C33AACD2581FD4931615CEE4B77BD3623BF5FCB37B0F2D6B252200D6F1BBF4A7016B02A68A38AF755D6EDB68DFF96BCD8C8177C8E059231E847&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B6351343F4791CA3&aid=7BA62EAAEF4CF3CAACA7CC93FE76FA52&vid=&iid=59906B3B2830C2C5&sid=2BCD2FED7562E194&eid=D4A72ABDCEDCE1BD&fileno=20191212&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B6351343F4791CA3"; var my_aid="7BA62EAAEF4CF3CAACA7CC93FE76FA52";