Zhang Qun,Zhang Liang,Zhang Dandan,Wang Aihong,Chen Bin,Hou Changsong,Zhu Weiguo,Ying Zhengju,Qu lingyan,Xu Guozhang.Study on informatization pattern of medical exposure frequency and dose monitoring[J].Chinese Journal of Radiological Medicine and Protection,2019,39(10):750-755 |
Study on informatization pattern of medical exposure frequency and dose monitoring |
Received:March 06, 2019 |
DOI:10.3760/cma.j.issn.0254-5098.2019.10.007 |
KeyWords:Medical exposure Informatization Frequency Dose |
FundProject: |
Author Name | Affiliation | E-mail | Zhang Qun | Department of Environmental and Occupational Health Promotion, Ningbo Municipal Center for Disease Control and Prevention, Ningbo 315010, China | | Zhang Liang | Department of Big Data Health Promotion, Ningbo Municipal Center for Disease Control and Prevention, Ningbo 315010, China | | Zhang Dandan | Department of Environmental and Occupational Health Promotion, Ningbo Municipal Center for Disease Control and Prevention, Ningbo 315010, China | | Wang Aihong | Department of Environmental and Occupational Health Promotion, Ningbo Municipal Center for Disease Control and Prevention, Ningbo 315010, China | | Chen Bin | Department of Radiology, Ningbo No.2 Hospital, Ningbo 315010, China | | Hou Changsong | Key Laboratory of Radiological Protection and Nuclear Emergency, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China | | Zhu Weiguo | Key Laboratory of Radiological Protection and Nuclear Emergency, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China | | Ying Zhengju | Department of Environmental and Occupational Health Promotion, Ningbo Municipal Center for Disease Control and Prevention, Ningbo 315010, China | | Qu lingyan | Department of Environmental and Occupational Health Promotion, Ningbo Municipal Center for Disease Control and Prevention, Ningbo 315010, China | | Xu Guozhang | Department of Big Data Health Promotion, Ningbo Municipal Center for Disease Control and Prevention, Ningbo 315010, China | xugz@nbcdc.org.cn |
|
Hits: 2464 |
Download times: 1192 |
Abstract:: |
Objective To realize the efficient monitoring of frequency of medical exposure and dose monitoring in Ningbo by means of informatization. Methods Data transmission process and the key elements of frequency of medical exposure and individual dose were investigated. According to standardization principles of data elements, the standardized data elements for frequency of medical exposure and individual dose were determined. On this basis, modules and functions of data receiving platform on the frequency of medical exposure and individual dose in Ningbo were designed. ResultsTotally 59 data elements on frequency of medical exposure and individual dose were formed. According to their functions, the data receiving platform was divided into the distribution of radiodiagnosis and radiotherapy resources, the frequency monitoring of medical exposure and dose monitoring for permanent residents, and the dose monitoring. Conclusions The establishment of frequency and dose information monitoring platform on medical exposure in Ningbo and the determination of standardized data elements will be conducive to further progress in medical exposure information monitoring in Ningbo. |
HTML View Full Text View/Add Comment Download reader |
Close |
|
|
|