Qiu Haijing,Gao Zhiling,Jia Jing,Chen Yuxin,Sun Wenjie,Chen Yong.Investigation of radiation dose in CT scanning for adult patients in Ningxia[J].Chinese Journal of Radiological Medicine and Protection,2019,39(9):691-696
Investigation of radiation dose in CT scanning for adult patients in Ningxia
Received:March 11, 2019  
DOI:10.3760/cma.j.issn.0254-5098.2019.09.010
KeyWords:CT  Radiation dose  Diagnostic reference level  Radiation dose optimization
FundProject:宁夏高等学校科学研究项目(NGY2016130);宁夏自治区重点研发计划项目(2018BFH030);贵州省大学生创新创业训练项目(201610660038);国家级大学生创新创业项目(宁夏医科大学大学生创新创业训练计划项目,201910752002)
Author NameAffiliationE-mail
Qiu Haijing Clinical Medical College of Ningxia Medical University, Yinchuan 750004, China  
Gao Zhiling Department of Radiology, General Hospital of Ningxia Medical University, Yinchuan 750004, China  
Jia Jing Department of Radiology, General Hospital of Ningxia Medical University, Yinchuan 750004, China  
Chen Yuxin Medical Imaging College of Guizhou Medical University, Guiyang 550025, China  
Sun Wenjie Clinical Medical College of Ningxia Medical University, Yinchuan 750004, China  
Chen Yong Department of Radiology and Intervention, General Hospital of Ningxia Medical University, Yinchuan 750004, China chenyong6981@sina.com 
Hits: 3653
Download times: 1232
Abstract::
      Objective To investigate the current status of CT radiation dose to adults in Ningxia, and provide basic data for developing the first diagnostic reference level of adults from CT scanning. Methods Stratified cluster sampling method was used to investigate the in-service status of CT scanners with various brands and different models in different grades of hospital in Ningxia. Interval sampling method was used to obtain everyday's scanning parameters and radiation dose values from different types of scanning examinations in surveyed hostipitals. Basic information was collected include hospitals, CT scanner, scanning types and patients. CT scanning parameters, CTDIvol and DLP values were recorded, with effective dose values calculated. The data were statistically analyzed by examination types and comparation was made with the DRL values recommended by other countries. Results Finally, there were 45 medical institutions in this study, including 10 public tertiary A hospitals, 5 public tertiary B hospitals, 23 public secondary A hospitals, 5 private hospitals and 2 physical examination centers. 58 CT scanners from 6 manufacturers and 4 952 adult patients were investigated. The 75th percentile (P75) of CTDIvol, DLP, and E values of common scanning examinations were listed as follows:65.67 mGy, 860.74 mGy·cm, and 1.64 mSv in skull scanning; 29.32 mGy, 490.00 mGy·cm, and 2.83 mSv in neck scanning; 36.92 mGy, 954.42 mGy·cm, and 4.87 mSv in neck enhanced scanning; 11.50 mGy, 382.06 mGy·cm, and 5.68 mSv in chest scanning; 45.80 mGy, 1 713.22 mGy·cm, and 25.01 mSv in chest enhanced scanning; 20.10 mGy, 506.59 mGy·cm, and 7.75 mSv in upper abdominal scanning; 50.07 mGy, 1 434.19 mGy·cm, and 21.94 mSv in upper abdominal enhanced scanning; 14.33 mGy, 670.78 mGy·cm, and 10.26 mSv in abdominal-pelvic scanning; 48.00 mGy, 2 294.00 mGy·cm, and 35.10 mSv in abdominal-pelvic enhanced scanning; 16.10 mGy, 471.58 mGy·cm, and 6.08 mSv in pelvic scanning; 31.04 mGy, 1 138.78 mGy·cm, and 14.69 mSv in pelvic enhanced scanning. Conclusions The CT scanning radiation doses to skull, neck, chest and pelvis in Ningxia are slightly lower than, or similar to, in other countries, but the abdominal scanning dose is significantly higher than that in other countries. It is necessary to optimize the abdominal CT scanning protocol.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9062568  On-line:0

v
Scan QR Code
&et=9A2B3ECE8B55D590E6E355423D82FAFD2174226F9FEEF8AB0390FFF925FCEF4917D33D3FB7E2C33DAC3101F48F52813A3F2B0857C922E6379CBE12982CE4B7F58B1E170169B7CD56137B07251B3CA26E&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B6351343F4791CA3&aid=7BA62EAAEF4CF3CA98CCEC9023F5DBF6&vid=&iid=9CF7A0430CBB2DFD&sid=09F7C8D609E885AE&eid=A7379F6713A46835&fileno=20190910&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B6351343F4791CA3"; var my_aid="7BA62EAAEF4CF3CA98CCEC9023F5DBF6";