Ge Jia,Ning Lihua,Yan Senxiang,Lu Zhongjie.Automatic segmentation of organs at risk for nasopharyngeal carcinoma with Smart Segmentation and MIM Atlas[J].Chinese Journal of Radiological Medicine and Protection,2019,39(9):668-672
Automatic segmentation of organs at risk for nasopharyngeal carcinoma with Smart Segmentation and MIM Atlas
Received:July 04, 2019  
DOI:10.3760/cma.j.issn.0254-5098.2019.09.006
KeyWords:Automatic contouring  Organs-at-risk segmentation  Atlas library  Nasopharyngeal carcinoma
FundProject:
Author NameAffiliationE-mail
Ge Jia Department of Radiation Oncology, the First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310006, China  
Ning Lihua Department of Radiation Oncology, the First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310006, China  
Yan Senxiang Department of Radiation Oncology, the First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310006, China  
Lu Zhongjie Department of Radiation Oncology, the First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310006, China luzhongjie@zju.edu.cn 
Hits: 3040
Download times: 1090
Abstract::
      Objective To compare the accuracy of two automatic segmentation softwares (Smart Segmentation and MIM Atlas) in organs at risk (OARs) contouring for nasopharyngeal carcinoma (NPC). Methods Totally 55 NPC patients were retrospectively reviewed with manually contoured OARs on CT images, in which 30 cases were randomly selected to create a data base in the Smart Segmentation and MIM Atlas. The remaining 25 cases were automatically contoured with Smart Segmentation and MIM as test cases. The automatic contouring accuracies of two softwares were evaluated with Dice coefficient(DSC), Hausdorff distance(HD), and absolute volume difference(△V) using manual contours as a golden standard. Results The overall DSC, HD and △V of all organs contoured by MIM Atlas and Smart Segmentation were (0.79±0.13) vs. (0.62±0.24) (t=14.06, P<0.05),(5.50±3.84)mm vs.(8.38±4.88)mm (t=-11.40, P<0.05),and (1.52±2.46) cm3 vs. (2.38±3.57) cm3 (t=-4.70, P<0.05), respectively. The average DSC of 11 organs (brain stem, optic chiasm, bilateral lens, bilateral optic nerve, bilateral eyeballs, bilateral parotid gland, spinal cord) delineated by MIM Atlas was statistically greater than that of Smart Segmentation (t=5.27, 4.41, 6.34, 5.70, 10.62, 7.45, 3.96, 4.26, 6.25, 5.42, 7.23, P<0.05). The average HD of 10 organs (brain stem, optic chiasm, bilateral lens, bilateral optic nerve, bilateral eyeballs, left parotid gland, spinal cord) delineated by MIM Atlas was statistically less than that of Smart Segmentation (t=-4.51, -4.49, -3.92, -3.45, -5.36, -5.56, -3.89, -3.90, -3.60, -3.68, P<0.05). The average △V of 6 organs (brain stem, optic chiasm, left len, bilateral optic nerve, right eyeball) delineated by MIM Atlas was statistically less than that of Smart Segmentation (t=-2.83, -3.39, -2.56, -2.27, -2.43, -2.51, P<0.05). Conclusions Both softwares have reasonable contouring accuracy for larger organs. The accuracy decreased with the decrease of organ volumes and blurred boundary. Generally, MIM Atlas's performs better than Smart Segmentation does.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9057281  On-line:0

v
Scan QR Code
&et=E6FEEF1BF80835174BF05B3714093E667E24B14378A13606A28FFA4F6EBE6AB63225C858363530932D2CD9636649DD1F8721034BF2865698012AB12DD1E34FC4531250204208B6D7115ACAF9C0F3CE1AF6BA0CF1B9BD0C83B3EAF5E0C486C6FFE14303C43A3AAA47BCBCD95701A4CE7B&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B6351343F4791CA3&aid=7BA62EAAEF4CF3CAF9B60CB49CADA37B&vid=&iid=9CF7A0430CBB2DFD&sid=C6FC2A9EA7E6C4B9&eid=B7DE0F3CA34DA149&fileno=20190906&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B6351343F4791CA3"; var my_aid="7BA62EAAEF4CF3CAF9B60CB49CADA37B";