Hu Shibei,Zhou Peng,He Changjiu,et al.Phantom study of the influence of CareDose 4D and Care kV on CT pulmonary ground glass nodule with respect to image quality and radiation dose[J].Chinese Journal of Radiological Medicine and Protection,2019,39(7):534-538
Phantom study of the influence of CareDose 4D and Care kV on CT pulmonary ground glass nodule with respect to image quality and radiation dose
Received:January 23, 2019  
DOI:10.3760/cma.j.issn.0254-5098.2019.07.010
KeyWords:CareDose 4D  Care kV  Ground glass nodule  Radiation dose  Image quality
FundProject:四川省科技计划项目(2017JY0080,2018SZ0183)
Author NameAffiliationE-mail
Hu Shibei Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology, Chengdu 610041, China  
Zhou Peng Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology, Chengdu 610041, China  
He Changjiu Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology, Chengdu 610041, China scszlyyhcj@sina.com 
Qing Haomiao Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology, Chengdu 610041, China  
Zhang Tao Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology, Chengdu 610041, China  
Peng Yubiao Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology, Chengdu 610041, China  
Li Deshan Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology, Chengdu 610041, China  
Hits: 3817
Download times: 1629
Abstract::
      Objective To investigate the effect of CareDose 4D combined with Care kV on CT pulmonary ground glass nodule (GGN) with respect to quality and radiation dose. Methods The thoracic model containing 6 GGN was performed by using 7 low-dose schemes. The CareDose 4D + Care kV was adopted in scheme 1. In schemes 2, 3 and 4, the tube voltage was 120 kV, and the tube current 30, 20 and 10 mAs respectively. In schemes 5, 6 and 7, the tube voltage was 100 kV, and the tube current was 30, 20 and 10 mAs, respectively. The image quality[CT value, contrast noise ratio (CNR), noise value (SD) and subjective score] and effective dose (E) were compared. Results There was no statistically significant difference in CT value of GGN among different schemes (P>0.05). The SD of scheme 1 was higher than those of schemes 2, 3 and 5, but lower than those f scheme 7, while the CNR of scheme 1 was lower than those of schemes 2, 3 and 5, but higher than that of scheme 7 (t=13.020, 9.560, 8.120, -5.720, -7.849, -5.192, -4.130, 1.361,P<0.05). SD and CNR of scheme 1 were not significantly different from those of scheme 4 and 6 (P>0.05). The subjective scores of each GGN of schemes 1, 2, 3, 5 and 6 was over 3 points, but and the subjective scores of one GGN of each of schemes 4 and 7 were below 3 points. The value E of the scheme 1 was reduced by 63.0%, 44.4%, 38.8%, and 9.1%, compared with the schemes 2, 3, 5 and 6, respectively. Conclusions CareDose 4D combined with Care kV in low-dose lung CT scan can ensure the image quality of GGN and reduce the radiation dose effectively.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12030053  On-line:0

v
Scan QR Code
&et=72BA01670B15E14C4349275228E099F9D54FB7500FD9FE8A654E85D656E6EDFBF5562764171EC8240F1FCE7D6DFA80CDCB118F28FEAB7416A55BD9F6418E5A931110C121C96B203EC210C150082A14E5151D290EF96BEBFA9543A32B5E9C4E15A2F9925EEB2F53C9552FA5DADA11C4A92F2DABCDAC76D00D14AF5D90B70B396201AE308AF59A99F08107FD5676891ADE&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B6351343F4791CA3&aid=7BA62EAAEF4CF3CA3F4067ACA1C6A886&vid=&iid=DF92D298D3FF1E6E&sid=D45762219109E903&eid=E49BED2EA9A8956B&fileno=20190710&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B6351343F4791CA3"; var my_aid="7BA62EAAEF4CF3CA3F4067ACA1C6A886";