Yu Peilin,Fan Wenliang,Lei Ziqiao,Yu Jianming.Size-specific dose estimation for chest CT examination in pediatric and adult patients[J].Chinese Journal of Radiological Medicine and Protection,2019,39(1):26-30
Size-specific dose estimation for chest CT examination in pediatric and adult patients
Received:August 13, 2018  
DOI:10.3760/cma.j.issn.0254-5098.2019.01.006
KeyWords:Size-specific dose estimates  Chest CT examination  Water equivalent diameter  Volume CT dose index  Children
FundProject:国家自然科学基金(81701673);湖北省自然科学基金(2017CFB796)
Author NameAffiliationE-mail
Yu Peilin Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China  
Fan Wenliang Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China fwl@hust.edu.cn 
Lei Ziqiao Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China  
Yu Jianming Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China  
Hits: 3106
Download times: 1655
Abstract::
      Objective To compare the differences in radiation doses from CT scanning between children of different age groups and adult patients by using both traditional radiation dose assessment parameters and size-specific dose estimates (SSDE).Methods A total of 406 patients undergoing lung CT examination were studied. They were sampled retrospectively and continuously from the Union Hospital and divided into six groups by age distritution (0-2, 3-6, 7-10, 11-14, 15-18, >18 years old). The CTDIvol and DLP values were randomly sampled using MATLAB platform-based dicom data software. The SSDE and water equivalent diameter were also calculated according to the AAPM 220 Report. The differences in radiation doses from lung CT scaning between children and adult patients were analysed.Results The CTDIvol values for all age groups were significantly lower than the SSDE values. The differences were statistically significant (t=-36.36, -32.83, -30.36, -28.74, -23.89, P<0.05). The SSDE values were 137%, 94%, 79%, 57% and 42% higher than the CTDIvol values, respectively. The CTDIvol values for the adult group were also lower than the SSDE values, and the difference was statistically significant (t=-21.92, P<0.05), and the SSDE value was about 41% higher than the CTDIvol value. With the increased age, CTDIvol value, DLP value, D\-w value and SSDE value for children of all age groups gradually increased and were significantly smaller than those for the adult group. The difference was statistically significant (F=63.39, 203.28, 89.27, 103.44, P<0.05). The conversion coefficient f for all age groups decreased significantly with age, which was significantly higher than that for the adult group, and the difference was statistically significant (F=109.83, P<0.05).Conclusions In lung CT scanning, the CTDIvol value significantly underestimated the radiation doses to children as compared to adults. CTDIvol values are more easily underestimated for younger patients. The SSDE method allows for more accurate reflection of the radiation doses to different patients, taking into account differences in the examined patient size.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9064536  On-line:0

v
Scan QR Code
&et=0AC591A045F42218A00BBD4B997B1149B256297EEF6FF591E15A041661F51EB83A5ED4059727B6B4833BAE299182E7524784782E49EAAC01FCA9EF9503FC7430E1B30FFFB631497100BC033355144A07A76543BEC172D302&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B6351343F4791CA3&aid=2BF99E2DE8AA5BC65E075FE055B5458C&vid=&iid=CA4FD0336C81A37A&sid=96C778EE049EE47D&eid=340AC2BF8E7AB4FD&fileno=20190106&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B6351343F4791CA3"; var my_aid="2BF99E2DE8AA5BC65E075FE055B5458C";