Pu Jin,Xia Chunchao,Zhao Fei,Li Lei,Zhang Kai,Li Yuming,Peng Wanlin,Zhang Jinge,Liu Keling,Xu Xu,Hu Sixian,Li Zhenlin.Application of dual-source CT combined with intelligent modulation and iterative reconstruction in aortic dissection imaging[J].Chinese Journal of Radiological Medicine and Protection,2019,39(1):6-10
Application of dual-source CT combined with intelligent modulation and iterative reconstruction in aortic dissection imaging
Received:January 24, 2018  
DOI:10.3760/cma.j.issn.0254-5098.2019.01.002
KeyWords:Emergency  Aorta  Interlayer  Angiography  CT
FundProject:四川省科技厅重点研发项目(2017SZ0016)
Author NameAffiliationE-mail
Pu Jin Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China  
Xia Chunchao Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China  
Zhao Fei Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China  
Li Lei Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China  
Zhang Kai Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China  
Li Yuming Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China  
Peng Wanlin Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China  
Zhang Jinge Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China  
Liu Keling Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China  
Xu Xu Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China  
Hu Sixian Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China  
Li Zhenlin Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China HX_lizhenlin@126.com 
Hits: 3183
Download times: 1310
Abstract::
      Objective To explore the clinical application value of second-generation dual-source CT combined with intelligent modulation and iterative reconstruction in emergency aortic dissection imaging.Methods A total of 40 emergency patients with clinical suspected aortic dissection were included in this study. Conventional scanning was performed in the control group, and large-pitch intelligent modulation and iterative reconstruction were performed in the test group. The mean CT value, mean noise, signal noise ratio(SNR), contrast noise ratio(CNR), effective dose, image quality and aortic root image quality were evaluated and analyzed.Results Totally 40 patients successfully completed CT aortic dissection imaging. There was no difference in image quality between the two groups(P>0.05). The quality of aortic root images in the test group was better than that in the control group, and the difference was statistically significant(χ2=22.556, P<0.05). The mean CT value and mean noise of aorta in the control group were slightly higher than those in the test group. However, SNR and CNR in the test group were higher than those in the control group, and the difference was statistically significant(t=-21.042, -15.924,8.530,11.495, P<0.05). The effective dose of the control group[(10.59±3.89)mSv] was significantly higher than that[(6.39±0.81)mSv] of the test group, the difference was statistically significant(t=-12.327,P<0.05).Conclusions The combined intelligent modulation technique and iterative reconstruction technique with dual-source CT large pitch scanning can meet the requirements of image quality and reduce the effective dose, and can be used as a conventional imaging method for emergency CT of aortic dissection.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9062011  On-line:0

v
Scan QR Code
&et=DCA5CABA83612A944859CF30E26D9D5281588577D4D62C1E0023CCA6BA75484C99DE7A5BFCBE5F58291B4DE881AE23E91CFCBFDC151C3FEB9A954D603A97858B9D9D40EF6882546503659F6FE229970CCD559B1333BD46AEF3CA9CD95BDC34AC30C6AB5FFE60802CF18FE3468ADB211D4DBC4CD3A329FCC01541E6997241A869&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=B6351343F4791CA3&aid=68A53CAB21A9BE93E028BDD3E5943D51&vid=&iid=CA4FD0336C81A37A&sid=B31275AF3241DB2D&eid=F3090AE9B60B7ED1&fileno=20190102&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="B6351343F4791CA3"; var my_aid="68A53CAB21A9BE93E028BDD3E5943D51";