Wang Qiang,Fu Qiang,Lin Lin.Cancer risk estimation in paedistric chest CT examination[J].Chinese Journal of Radiological Medicine and Protection,2018,38(8):607-611
Cancer risk estimation in paedistric chest CT examination
Received:February 07, 2018  
DOI:10.3760/cma.j.issn.0254-5098.2018.08.009
KeyWords:Computed tomography  Size-specific dose estimation  Organ dose  Lifetime attributable risk
FundProject:
Author NameAffiliation
Wang Qiang Department of Occupational Disease Prevention, Changzhou Center for Disease Control and Prevention, Changzhou 213022, China 
Fu Qiang Department of Occupational Disease Prevention, Changzhou Center for Disease Control and Prevention, Changzhou 213022, China 
Lin Lin Department of Occupational Disease Prevention, Changzhou Center for Disease Control and Prevention, Changzhou 213022, China 
Hits: 3675
Download times: 1884
Abstract::
      Objective To estimate the lifetime attributable risk (LAR) of lung cancer, stomach cancer, liver cancer, thyroid cancer, breast cancer and leukemia for 1-, 5-and 10-year old children undergoing chest CT scan.Methods Chest CT images of children was retrieved from the picture archiving and communication system (PACS) and the average CT number and area of the region of interest (ROI) were read on the CT work station. Water equivalent diameter were calculated according to the method recommended by the American Association of Physicists in Medicine (AAPM). Furthermore, the size-specific dose estimation (SSDE) was made based on the water equivalent diameter and the volume computed tomography dose index(CTDIvol). Based on the method recommended by Caro Franck, the SSDE then was converted into average organ doses to lung, stomach, liver, thyroid, breast and blood for children at different ages and of different sex undergoing chest CT scan. On the basis of average organ dose, the cancer risk prediction model from the National Academy of Science's Biological Effects of Ionizing Radiation-Ⅶ (BEIR-Ⅶ) was used to predict the LAR for different cancers mentioned above. For lung cancer, gastric cancer, liver cancer and leukemia, the calculating sequence was from average organ dose to excess relative risk (ERR) to LAR, whereas for the thyroid cancer and breast cancer, the sequence was from ERR to average organ dose to LAR.Results The average organ dose to lung, stomach, liver, thyroid, breast and blood for children at different age and of different sex undergoing chest CT scan was obtained. The age had a statistically significant impact on the SSDE(t=24.28, P<0.05), but sex has not(P>0.05). LAR for lung cancer, gastric cancer, liver cancer, thyroid cancer, breast cancer and leukemia for 1-, 5-and 10-year old children undergoing chest CT scan was obtained, among whom the LAR for thyroid cancer and breast cancer was relatively high. The LAR for women breast cancer was 10.9 per 100 000 persons for 1 year old children, 30.8 per 100 000 persons for 5 years old and 34.5 per 100 000 persons for 10 years old.Conclusions With introduction of new technologies, the radiation dose due to chest CT scan is on the decline. But the induced radiation dose is still significant compared with general diagnostic radiography. The risk of cancer still deserves more attention and should be taken into consideration in the justification of diagnostic radiology.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9065884  On-line:0

v
Scan QR Code
&et=0242291A86E7A8A2E37C586A147F756FAA0F8AD02C09FCB0E3BB7A5B0F578E7F44D80626055ED93347042AA2A33D540D270F7E40C106D154723904A0FD383295&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=EA357AD73C8E13BC&aid=415CD46E06B7C80CEB7864E72AD782B1&vid=&iid=5D311CA918CA9A03&sid=D647AF4730396036&eid=FED67FBA0A707330&fileno=20180809&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="EA357AD73C8E13BC"; var my_aid="415CD46E06B7C80CEB7864E72AD782B1";