Zhang Xuan,Guo Wen,Ding Yanqiu,Xu Hui.The review of individual effective dose monitoring method for interventional radiology staff[J].Chinese Journal of Radiological Medicine and Protection,2018,38(5):395-400
The review of individual effective dose monitoring method for interventional radiology staff
Received:January 12, 2018  
DOI:10.3760/cma.j.issn.0254-5098.2018.05.014
KeyWords:Interventional radiology staff  Individual effective dose monitoring  Algorithm
FundProject:
Author NameAffiliationE-mail
Zhang Xuan Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Guo Wen Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China guowen_cn@126.com 
Ding Yanqiu Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Xu Hui Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Hits: 3252
Download times: 1614
Abstract::
      To present an overview of the indicators of effective dose equivalent assessment in interventional radiology and dosimetry algorithms, together with some problems attracting controversy so far. By literature consultation at home and abroad, some discussions were made on dosimetry algorithms in interventional radiology worldwide, main factors affecting accuracy of the method and the discussions on the optimal position of dosimeter. Suggestions are made on the basis of the recent research result and present dosimeters wearing conditions for reference.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9063307  On-line:0

v
Scan QR Code
&et=4913522D3BBDA6F0E8466D22AC2E4CAC043B781AFADFB3726A8903FBE7BB677F254FC848519CA2105D792DF1EFA26A895AA3EB716A504C12F820586CF86A91BD437751AD31CA2F43537BB1D5C6BA985C0744D69469FD3B6CBACF8FED5EFBB8D6&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=EA357AD73C8E13BC&aid=415CD46E06B7C80C273163D284725F55&vid=&iid=94C357A881DFC066&sid=396DD691E964F390&eid=8ACD9060100C26F1&fileno=20180514&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="EA357AD73C8E13BC"; var my_aid="415CD46E06B7C80C273163D284725F55";