He Chuang,Chen Yuxiao,Li Liangshan,Yang Li,Yuan Jing,Li Tingyuan,Huang Xuequan.A comparative study on the accuracy of longitudinal distance between 125I seed implantation with degradable catheters and by hand[J].Chinese Journal of Radiological Medicine and Protection,2018,38(3):220-223
A comparative study on the accuracy of longitudinal distance between 125I seed implantation with degradable catheters and by hand
Received:August 29, 2017  
DOI:10.3760/cma.j.issn.0254-5098.2018.03.012
KeyWords:Degradable catheter  125I seeds  Brachytherapy  CT guidance
FundProject:
Author NameAffiliationE-mail
He Chuang Department of Radiology, Southwest Hospital, Army Medical University(Third Military Medical University), Chongqing 400038, China  
Chen Yuxiao Department of Radiology, Southwest Hospital, Army Medical University(Third Military Medical University), Chongqing 400038, China  
Li Liangshan Department of Radiology, Southwest Hospital, Army Medical University(Third Military Medical University), Chongqing 400038, China  
Yang Li Department of Radiology, Southwest Hospital, Army Medical University(Third Military Medical University), Chongqing 400038, China  
Yuan Jing Department of Radiology, Southwest Hospital, Army Medical University(Third Military Medical University), Chongqing 400038, China  
Li Tingyuan Department of Radiology, Southwest Hospital, Army Medical University(Third Military Medical University), Chongqing 400038, China  
Huang Xuequan Department of Radiology, Southwest Hospital, Army Medical University(Third Military Medical University), Chongqing 400038, China hxuequan@163.com 
Hits: 2314
Download times: 1921
Abstract::
      Objective To compare the accuracy of 125I seeds longitudinal distance between groups by degradable catheters and hand. Methods The study was divided into two groups (implantation by degradable catheters and that by hand). There were 12 simulated lesions in each group. Seed needle and 125I seeds were implanted by three physicians according to the set longitudinal distance (0.5 and 1.0 cm). Postoperative CT was conducted and the longitudinal distance between seeds was measured, and then the data was analyzed between the actual distance and the designed distance in each group. Results The degree of deviation from the set distance were (0.184±0.047) and (0.127±0.051) cm in the group by hand, and (0.007±0.006) and (-0.003±0.006) cm in degradable catheters group. The degree of deviation of the seeds in the catheter group was significantly lower than the group by hand (t=3.804, 2.499, P<0.05). Conclusions The accuracy of the longitudinal distance of the group by catheter is much better than that by hand.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9060069  On-line:0

v
Scan QR Code
&et=8E4FC607531F30FE26E3E977424F764A25A368005729C5BC46FD3154D028A78028FF8D3F3B8158C8B6F2BD674092B9CFD58EB06F8382E8F225E1EBAA13518A5F8DCCF010A65ECE17AF4E47FFC870F0534667488340365DBB36313634F4AD4C20567B1C1B1470D958B394B3701B202B93D2956A7A755DDC4F07DEBBB90C0EF1ACADAB12970B6CE9AF0291955D7BCDFF27&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=EA357AD73C8E13BC&aid=CE8D2B25BC256F5A567A2323AD65CBEF&vid=&iid=38B194292C032A66&sid=1D67BE204FBF4800&eid=E089FDF3CDAE8561&fileno=20180312&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="EA357AD73C8E13BC"; var my_aid="CE8D2B25BC256F5A567A2323AD65CBEF";