Jin Xiaoli,Hao Lin,Shi Qinying,Lu Ying,An Junxuan,Song Jianbo.Feasibility study on setting the breast board support plate angle to 0°[J].Chinese Journal of Radiological Medicine and Protection,2017,37(9):681-685
Feasibility study on setting the breast board support plate angle to 0°
Received:June 04, 2017  
DOI:10.3760/cma.j.issn.0254-5098.2017.09.008
KeyWords:Breast cancer  Intensity modulated radiation therapy  Breast board  Setup error
FundProject:
Author NameAffiliationE-mail
Jin Xiaoli Department of Radiation Oncology, Shanxi Dayi Hospital, Tai Yuan 030031, China  
Hao Lin Department of Radiation Oncology, Shanxi Dayi Hospital, Tai Yuan 030031, China  
Shi Qinying Department of Radiation Oncology, Shanxi Dayi Hospital, Tai Yuan 030031, China  
Lu Ying Department of Radiation Oncology, Shanxi Dayi Hospital, Tai Yuan 030031, China  
An Junxuan Department of Radiation Oncology, Shanxi Dayi Hospital, Tai Yuan 030031, China  
Song Jianbo Department of Radiation Oncology, Shanxi Dayi Hospital, Tai Yuan 030031, China 784408955@qq.com 
Hits: 3161
Download times: 2025
Abstract::
      Objective To explore the feasibility to set the breast board support plate angle to 0° for breast cancer patient in the intensity modulated radiation therapy.Methods A total of 60 patients with breast cancer who received the simultaneous integrated boost intensity-modulated radiation therapy (SIB-IMRT) after breast-conserving surgery were enrolled form Oct 2015 to Feb 2017. They were randomly divided into three groups that the angle of the breast board support plate was 12°, 7° and 0° respectively. The ipsilateral lung V20, V5, Dmean, the heart V10, V30, Dmean and the collimator angle were compared among three groups. In addition, the distribution of the setup error was analyzed and the group system error and random error were calculated.Results There were no statistically significant differences in the ipsilateral lung V20, V5, Dmean and the heart V10, V30, Dmean among the three groups(P>0.05).The sum of the collimator angle and the angle of the support plate was about 13.4° for each group. Only the setup error of z (vertical) direction was statistically different (χ2=78.32, P<0.001) and the median of the 0° group was closest to the value 0 and the quartile spacing was the smallest. The absolute error of y (longitudinal), z directions was statistically different (χ2=7.63, 22.61,P<0.05). In the z direction, the absolute error was reduced as the angle of the support plate decreased and 0°group was the smallest. In the y direction, the absolute error at 12° was the smallest, but had little difference with that at 0°. Among three groups, the smallest system error of the x(lateral) direction and y direction was at 0°, while that of the z direction was at 12°.Conclusions To set the breast board support plate 0° is feasible. The angle of the support plate can be replaced by the collimator angle, while the setup error of z direction could be significantly reduced.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9074377  On-line:0

v
Scan QR Code
&et=08BA79BB04C4219F9D0A59D56E3175C4A2C16243A815A4DA584718B03861B6D81BCE05D250BF38CB45DEC1B90AE2560CA2DE6550DF133C5C2B488DFFB8712506481528DC681A1E704FA69E198DB60E20&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FA004A8A4ED1540B&aid=&vid=&iid=9CF7A0430CBB2DFD&sid=8243B77967FFD12E&eid=AF14A8B15FB15A64&fileno=20170909&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FA004A8A4ED1540B"; var my_aid="";