Cao Qiang,Huo Bin,Huo Xiaodong,Wang Jinhuan,Wang Lei,Zang Li,Hou Dingkun,Wang Haitao,Wang Junjie,Chai Shude.Dosimetric study of 3D-printing coplanar template combined with CT-guided 125Ⅰ seed implantation for treating non-small cell lung cancer[J].Chinese Journal of Radiological Medicine and Protection,2017,37(7):528-532
Dosimetric study of 3D-printing coplanar template combined with CT-guided 125Ⅰ seed implantation for treating non-small cell lung cancer
Received:April 05, 2017  
DOI:10.3760/cma.j.issn.0254-5098.2017.07.011
KeyWords:3D-printing  Coplanar template  Free hand  125Ⅰ seed implantation  Non small cell lung cancer
FundProject:国家自然科学基金(81572543);天津市自然科学基金(15JCYBJC28400)
Author NameAffiliationE-mail
Cao Qiang Department of Oncology, The Second Hospital of Tianjin Medical University, Tianjin 300211, China  
Huo Bin Department of Oncology, The Second Hospital of Tianjin Medical University, Tianjin 300211, China  
Huo Xiaodong Department of Oncology, The Second Hospital of Tianjin Medical University, Tianjin 300211, China  
Wang Jinhuan Department of Oncology, The Second Hospital of Tianjin Medical University, Tianjin 300211, China  
Wang Lei Department of Oncology, The Second Hospital of Tianjin Medical University, Tianjin 300211, China  
Zang Li Department of Oncology, The Second Hospital of Tianjin Medical University, Tianjin 300211, China  
Hou Dingkun Department of Oncology, The Second Hospital of Tianjin Medical University, Tianjin 300211, China  
Wang Haitao Department of Oncology, The Second Hospital of Tianjin Medical University, Tianjin 300211, China peterrock2000@126.com 
Wang Junjie Department of Thoracic Surgery, The Second Hospital of Tianjin Medical University, Tianjin 300211, China  
Chai Shude Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Hits: 3062
Download times: 1719
Abstract::
      Objective To explore the safety, effectivity and dosimetric continence of 3D-printing coplanar template(3D-PCT)combined with CT-guided 125Ⅰ seed implantation in the treatment of non-small cell lung cancer(NSCLC). Methods From May 2014 to November 2016, a total of 20 NSCLC patients who were suitable for 125Ⅰ seed implantation were recruited in this study. Of all the patients, 10 received 125Ⅰ seed implantation treatment by CT-guided combined with 3D-PCT (3D group), and the rest, by free-hand puncture combined with CT-guided 125Ⅰ seed implantation (free-hand group). During two days before the surgery, the patients received the CT scan. Then the digital imaging and communications in medicine(DICOM) was collected to input to the Brachytherapy Treatment Planning System(BTPS). The dose parameters including D90, D100,V100, V150, conformal index(CI), external index(EI),and homogneneity index(HI) were compared between pre-operation and post-operation. Pair t-test and single sample t-test were performed. Results V150 in 3D group between preoperation and postoperation showed statistically significant difference(t=-2.916, P< 0.05), and there was no significant difference in the rest parameters(P> 0.05). However, the number of seeds, V100, EI, HI in free-hand group between preoperation and postoperation showed statistically significant difference(t=-2.516, 2.492, 4.725, 7.258, P< 0.05), and there was no significant difference in the rest parameters(P> 0.05). Comparison of indicuted that there was significant difference in V100, V150, CI, EI, HI and dose error rate between the 3D group and the free-hand group with single sample t test,the result showed V100, CI, EI, HI between two groups(t=2.598, 2.278, 4.637, 4.616, -4.785, P< 0.05),and there was no significant difference in V150 (P> 0.05). Conclusions CT-guided 125Ⅰ seed implantation brachytherapy combined with 3D-PCT for treatment of NSCLC safe is feasible, and dose controllable, and there is a certain advantage in the spatial distribution of seed compared with free-hand puncture.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9066320  On-line:0

v
Scan QR Code
&et=8400690B225D0A443DE87302E95E1010CCF180EF4BDCDAED7C64D82DDD2AB6B54C3A67CAFB4ADAF0A8FBC44B552DDAD72D1CBF00B81BFAA08E5F816AE302CC15525CEB71D16101E8C61465F8EB0C79133BDBF68A8EE70D8FE7EF9945BB71E4F89A966329A7E6E3A32E5CB5C84ABE8F2204ECE4E7E928D3503540978C153ABAEFD9E203D4291C7A1CE8A577534081B7AC3693511C98D87410&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FA004A8A4ED1540B&aid=BF88AFC87C5C19B4F2D8425A17D57046&vid=&iid=DF92D298D3FF1E6E&sid=652E7E360EBE3082&eid=640CCB6E396307A8&fileno=20170711&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FA004A8A4ED1540B"; var my_aid="BF88AFC87C5C19B4F2D8425A17D57046";