Xing Chao,Zhang Kaixian,Yuan Qianqian,Hu Miaomiao,Wu Linlin,Man Qirong,Yang Sen,Li Peishun,Wang Baohu,Wang Junjie.Dosimetry verification of radioactive seed implantation for malignant tumor assisted by 3D-printing coplanar template[J].Chinese Journal of Radiological Medicine and Protection,2017,37(7):514-517
Dosimetry verification of radioactive seed implantation for malignant tumor assisted by 3D-printing coplanar template
Received:April 07, 2017  
DOI:10.3760/cma.j.issn.0254-5098.2017.07.008
KeyWords:3D-printing  Coplanar template  Radioactive seed implantation  Dosimetry  Malignant tumor
FundProject:
Author NameAffiliationE-mail
Xing Chao Department of Oncology, Tengzhou Central People's Hospital, Tengzhou 277599, China  
Zhang Kaixian Department of Oncology, Tengzhou Central People's Hospital, Tengzhou 277599, China kaixianzhang@aliyun.com 
Yuan Qianqian Department of Oncology, Tengzhou Central People's Hospital, Tengzhou 277599, China  
Hu Miaomiao Department of Oncology, Tengzhou Central People's Hospital, Tengzhou 277599, China  
Wu Linlin Department of Oncology, Tengzhou Central People's Hospital, Tengzhou 277599, China  
Man Qirong Department of Oncology, Tengzhou Central People's Hospital, Tengzhou 277599, China  
Yang Sen Department of Oncology, Tengzhou Central People's Hospital, Tengzhou 277599, China  
Li Peishun Department of Oncology, Tengzhou Central People's Hospital, Tengzhou 277599, China  
Wang Baohu Department of Oncology, Tengzhou Central People's Hospital, Tengzhou 277599, China  
Wang Junjie Department of Radiation Oncology, Peking University Third Hospital, Bejing 10091 China  
Hits: 2517
Download times: 2058
Abstract::
      Objective To compare the dose distribution of postoperative plans with preoperative plans for 3D printing coplanar template assisted radioactive seed implantation,and to explore the accuracy of the technique in seed implantation. Methods From November 2015 to December 2016 a total of 32 patients were selected and underwent 3D printing coplanar template assisted radioactive seed implantation in Tengzhou Central People's Hospital of Shandong province. There were 36 implanted lesions,including 10 in the lungs,5 in neck lymphs,3 in pelvic cavities,3 in vertebral body,2 in pancreas,2 in abdominal lymph nodes,2 in portal veins,and 9 in the other parts. All patients were given preoperative planning and guided by the coplanar templates. Compared with the preoperative plan, all levels needles inserted at the same time. According to preoperative planning the implantation surgery was completed accurately. The postoperative dosimetry was evaluated. The preoperative and postoperative dosimetry parameters were compared, including D90,D100,V90,V100, V150,V200 and conformal index(CI),external index(EI),and homogeneity index(HI). The paired t test was used to perform the statistical analysis.Result There was no significant differences in D90,D100,V90,V100, V150, V200, CI, EI and HI between before and after operation(P>0.05). Conclusions The dose parameters in postplan showed no difference compared with preplan in this study. For fixed and moving organ tumors,3D printing coplanar template assisted radioactive seed implantation has good therapeutic accuracy,and may be a standardized surgicalmethod for seed implantation in the future.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9060231  On-line:0

v
Scan QR Code
&et=8400690B225D0A4443FBBC25B7F89184BB82AD6AFA2F289F511DBD93BA655F0C07C2C97AA108405CC484E07D34616E6C6425DAFC209420DEE3E31547C7FA004A931998465557A46613DF77748AD841DBA681D4417BA646158418E22376ECB5B538D7D80D34C6CBF5640891F4A45947B02C345D1220268F4F&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FA004A8A4ED1540B&aid=BF88AFC87C5C19B47DDA4F37A7D289BB&vid=&iid=DF92D298D3FF1E6E&sid=C4BBAD7A2DCC89BC&eid=5A751AE9FA58A3FB&fileno=20170708&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FA004A8A4ED1540B"; var my_aid="BF88AFC87C5C19B47DDA4F37A7D289BB";