Wu Yunyun,Mei Aihua,Zhang Yonggui,et al.Study on relationship between indoor radon concentration and air exchange rate for new residential buildings[J].Chinese Journal of Radiological Medicine and Protection,2017,37(6):451-455
Study on relationship between indoor radon concentration and air exchange rate for new residential buildings
Received:December 23, 2016  
DOI:10.3760/cma.j.issn.0254-5098.2017.06.010
KeyWords:New residential building  Energy-saving design  Indoor  Radon concentration  Air exchange rate
FundProject:国家自然科学基金(11375164)
Author NameAffiliationE-mail
Wu Yunyun Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Mei Aihua Guangzhou Institute of Building Science, Guangzhou 510440, China  
Zhang Yonggui China Building Material Test and Certification Group Co., Ltd., Beijing 100024, China  
Wang Junlin Department of Engineering Physics, Tsinghua University, Beijing 100084, China  
Shang Bing Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Cui Hongxing Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China hxcuicn@163.com 
Hits: 3803
Download times: 2379
Abstract::
      Objective To investigate the relationship between indoor radon concentration and air exchange rate for new residential building. Methods The indoor radon concentration and air exchange rate were measured in two new roughcast houses in Guangzhou and Hefei,respectively.The radon concentration was measured using radon instrument.The air exchange rate was measured by using tracer gas dilution method. Results The indoor radon concentrations measured in Guanzhou for two bedrooms in a 48-hour closed condition were 106 and 115 Bq/m3,the range of 17-181 and 6-224 Bq/m3.Air exchange rates were 0.16/h and 0.21/h.In Hefei,the twice measured values for one bedroom were 148 and 186 Bq/m3,the range of 8-224 and 14-290 Bq/m3,and air exchange rates were 0.14/h and 0.12/h.The indoor radon concentration exponentially decreased with the increase of air exchange rates. Conclusions Attention should be paid to the indoor radon pollution issue that may arise in new residential buildings of energy-saving design due to low air exchange rate.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12031265  On-line:0

v
Scan QR Code
&et=08EE5A5866ACE44096D25B547C5087E6F8980918808D2C4A7286989010431AEE9FE1325C191011CD2B064CC982FCA40308ECF39F96ED57B1E901E6424E29B812DC315FD89D1051C5C135DB2F1B9F3AB3CCCA9493984943AAD3F745776BCE676E97B91FBD3D088CA60F3B7DD600AC0701&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FA004A8A4ED1540B&aid=6DF7CB66686A5806845A62DACC7D09F2&vid=&iid=B31275AF3241DB2D&sid=9B95A71E6639C039&eid=366B1248A15658C5&fileno=20170610&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FA004A8A4ED1540B"; var my_aid="6DF7CB66686A5806845A62DACC7D09F2";