Wu Yunyun,Mei Aihua,Zhang Yonggui,et al.Study on relationship between indoor radon concentration and air exchange rate for new residential buildings[J].Chinese Journal of Radiological Medicine and Protection,2017,37(6):451-455 |
Study on relationship between indoor radon concentration and air exchange rate for new residential buildings |
Received:December 23, 2016 |
DOI:10.3760/cma.j.issn.0254-5098.2017.06.010 |
KeyWords:New residential building Energy-saving design Indoor Radon concentration Air exchange rate |
FundProject:国家自然科学基金(11375164) |
Author Name | Affiliation | E-mail | Wu Yunyun | Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China | | Mei Aihua | Guangzhou Institute of Building Science, Guangzhou 510440, China | | Zhang Yonggui | China Building Material Test and Certification Group Co., Ltd., Beijing 100024, China | | Wang Junlin | Department of Engineering Physics, Tsinghua University, Beijing 100084, China | | Shang Bing | Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China | | Cui Hongxing | Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China | hxcuicn@163.com |
|
Hits: 3803 |
Download times: 2379 |
Abstract:: |
Objective To investigate the relationship between indoor radon concentration and air exchange rate for new residential building. Methods The indoor radon concentration and air exchange rate were measured in two new roughcast houses in Guangzhou and Hefei,respectively.The radon concentration was measured using radon instrument.The air exchange rate was measured by using tracer gas dilution method. Results The indoor radon concentrations measured in Guanzhou for two bedrooms in a 48-hour closed condition were 106 and 115 Bq/m3,the range of 17-181 and 6-224 Bq/m3.Air exchange rates were 0.16/h and 0.21/h.In Hefei,the twice measured values for one bedroom were 148 and 186 Bq/m3,the range of 8-224 and 14-290 Bq/m3,and air exchange rates were 0.14/h and 0.12/h.The indoor radon concentration exponentially decreased with the increase of air exchange rates. Conclusions Attention should be paid to the indoor radon pollution issue that may arise in new residential buildings of energy-saving design due to low air exchange rate. |
HTML View Full Text View/Add Comment Download reader |
Close |
|
|
|