Lu Xiaoguang,Ohtani Hiroki.Development and application of radiation shielding device for radiation survey detector[J].Chinese Journal of Radiological Medicine and Protection,2017,37(4):282-285
Development and application of radiation shielding device for radiation survey detector
Received:October 13, 2016  
DOI:10.3760/cma.j.issn.0254-5098.2017.04.010
KeyWords:Radiation level  Fukushima  Decontamination  Radiation survey meter  Radiation shielding
FundProject:山东省自然科学基金联合专项(ZR2015HL100)
Author NameAffiliation
Lu Xiaoguang Department of Oncology, Tongji Hospital Affiliated to Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China 
Ohtani Hiroki Department of Radiological Sciences, Tokyo Metropolitan University, Tokyo 116-8551, Japan 
Hits: 2558
Download times: 1745
Abstract::
      Objective To develop the radiation shielding device for an environmental radiation survey meter with an aim to precisely measure local radiation levels and evaluate decontamination effectiveness in Fukushima.Methods A kind of lead alloy was selected as the main material for the shielding device. Attenuation effects of different lead plates and lead cylinders were measured at the radiation regulatory laboratory and in a polluted area of Fukushima, respectively. The whole shielding device was designed on the basis of measurement results, attenuation effects, cost of production and practicability. Results The whole device was composed of main shielding, probe shielding and a bracket with lid. The main shielding was a lead cylinder with 10 cm in height and 3 cm in thickness. The probe shielding was a lead cylinder with 8 cm in height and 2 cm in thickness. The thickness of lid was 1 cm. Conclusions The device can be available to effectively shield the influence of ambient radiation and accurately measure local radiation levels and evaluate decontamination effectiveness. It can play a valuable part in post-disaster reconstruction of contaminated areas in Fukushima.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9074192  On-line:0

v
Scan QR Code
&et=A90EAC7419FB9B227A2C8A1A37B10BA7EF57F099C7EF6EE03DD9E57216D6FFAD2C35F2C0478519AE05A2E9F9ADCBFFED0446FB6BA150C426CAB610B6310E3C4A779648EC3317C092E048740DE05C96B35FB973A22E25E219&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FA004A8A4ED1540B&aid=235426790044AA8648FF0A487B7F7FA0&vid=&iid=E158A972A605785F&sid=4133DDB79B497495&eid=B8F8200D88DDC7D6&fileno=20170409&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FA004A8A4ED1540B"; var my_aid="235426790044AA8648FF0A487B7F7FA0";