Yan Huifeng,Zhang Li,Zhang Zhaotao,Yao Bin,Liu Ying,Zuo Minjing,Li Xiao,Huang Shuiping.Dual-source CT with high-pitch, low tube voltage and iterative reconstruction in preoperative evaluation of transcatheter aortic valve replacement[J].Chinese Journal of Radiological Medicine and Protection,2017,37(2):149-154
Dual-source CT with high-pitch, low tube voltage and iterative reconstruction in preoperative evaluation of transcatheter aortic valve replacement
Received:October 11, 2016  
DOI:10.3760/cma.j.issn.0254-5098.2017.02.012
KeyWords:Dual-source CT  High pitch  Low tube voltage  Iterative reconstruction  Transcatheter aortic valve replacement (TAVR)
FundProject:
Author NameAffiliationE-mail
Yan Huifeng Department of CT The Second Affiliated Hospital of Nanchang University, 330006 Nanchang, China  
Zhang Li Department of Neurology, The Second Affiliated Hospital of Nanchang University, 330006 Nanchang, China  
Zhang Zhaotao Department of CT The Second Affiliated Hospital of Nanchang University, 330006 Nanchang, China  
Yao Bin Department of CT The Second Affiliated Hospital of Nanchang University, 330006 Nanchang, China  
Liu Ying Department of CT The Second Affiliated Hospital of Nanchang University, 330006 Nanchang, China  
Zuo Minjing Department of CT The Second Affiliated Hospital of Nanchang University, 330006 Nanchang, China 124542022@qq.com 
Li Xiao Department of CT The Second Affiliated Hospital of Nanchang University, 330006 Nanchang, China  
Huang Shuiping Department of CT The Second Affiliated Hospital of Nanchang University, 330006 Nanchang, China  
Hits: 2889
Download times: 1683
Abstract::
      Objective To investigate the value of Dual-source CT with low tube voltage(kV), high-pitch, and iterative reconstruction in preoperative evaluation of transcatheter aortic valve replacement(TAVR).Methods Sixty patients with suspected aortic stenosis who underwent thoraco-abdominal CT angiography (CTA) were divided into three groups (n=20) using a table of random numbers method (simple high-pitch group, combined high-pitch, low-kV and iterative reconstruction group and conventional group). Subjective and objective scores of image quality, contrast dosage and radiation dose of three groups were compared. Results The subjective scores of image quality were seen in only three cases in conventional group which met preoperative assessment of TAVR, and were significantly higher in high-pitch group and combined group than those in conventional group(t=17.083,16.667,P<0.05) with no statistically significant difference(P>0.05) between high-pitch group and combined group. There was no statistical significance among three groups about the objective evaluation of image quality. The dosage contrast medium in high-pitch group and combined group were significantly less than that in conventional group (t=-13.645,-14.647,P<0.05), but there was not statistically difference (P>0.05) between high-pitch group and combined group. The volume CT dose index(CTDIvol), dose length product (DLP) and the effective dose(E) values of combined group were significantly lower than those in high-pitch group and conventional group, and there were statistically different among three groups(F=2 564.398,651.616,653.308,P<0.05). Conclusions The Dual-source CT with low tube voltage, high-pitch and iterative reconstruction could meet the requirement of image quality for preoperative assessment of TAVR, and greatly reduce the dose of radiation and contrast medium.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9075049  On-line:0

v
Scan QR Code
&et=892582B02D244B0A39EB06CA730707997BFA4CA72F6D245FD04F8CE12EDC154230001433D3E2DA5E55C6B76C9FF9BC542E41F08D02DD3EEC76D86412CE2C8DEA8F68D74D1F336C55B9E4A23C37CDBEEECB7A318CDFA72654B62A7472416FE35243D11CF027BCDEDFE62FA6158A6D1E86AD1BB41C50C86F65A997C40D1A97186D63EA04D4767D64F82EB7B108A0C1A8BD858EB4030BDBBCBB&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FA004A8A4ED1540B&aid=B0C8D2BC997AC2973E54F7841B404D69&vid=&iid=0B39A22176CE99FB&sid=EB552E4CFC85690B&eid=E2546871E5B846EF&fileno=20170212&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FA004A8A4ED1540B"; var my_aid="B0C8D2BC997AC2973E54F7841B404D69";