Jiang Yuliang,Li Bin,Ji Zhe,et al.Analysis of position errors of 3D printing individual non-coplanar template for radioactive seed implantation for malignant tumor[J].Chinese Journal of Radiological Medicine and Protection,2016,36(12):913-916
Analysis of position errors of 3D printing individual non-coplanar template for radioactive seed implantation for malignant tumor
Received:June 14, 2016  
DOI:10.3760/cma.j.issn.0254-5098.2016.12.007
KeyWords:3D printing  Template  Radioactive seed implantation  Errors
FundProject:首都临床特色应用研究与成果推广项目(Z151100004015171)
Author NameAffiliationE-mail
Jiang Yuliang Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Li Bin Department of Radiation Oncology, Luoyang Gentral Hospital Affiliated to Zhengzhou University, Luoyang 471000, China  
Ji Zhe Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Guo Fuxin Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Sun Haitao Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Fan Jinghong Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Li Xu Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Zhang Lujing Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Wang Junjie Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China junjiewang_edu@sina.cn 
Hits: 5146
Download times: 2790
Abstract::
      Objective To investigate the accuracy and errors of 3D printing individual non-coplanar template (3D printing template) for 125I seed implantation in head and neck, thoracic and pelvic recurrent carcinoma.Methods From 2015 to 2016, a total of 41 patients treated with 125I seed implantation under 3D printing template were analyzed. All of them were conducted with CT-simulator scan two days before operation. The x and y axis position errors of 3D printing template between pre- and intro-operation plan, and set-up error in different site and position were analyzed. Results The x and y axis 3D individual non-coplanar template set-up position errors in head and neck, thoracic and pelvic location were (1.77±1.09), (2.66±1.65), (4.00±1.41), (5.22±1.85), (1.88±1.29) and (2.52±1.37) mm, respectively. Compared with thoracic, statistically significant difference was found in the head and neck and pelvic in x and y axis position errors (t=-3.730, -3.080, -3.944, -4.519, P<0.05). No statistically significant difference was observed in other results (P<0.05). Conclusions 3D printing individual non-coplanar template assistant I-125 seed implantation are more accurate and efficiency.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11565159  On-line:0

v
Scan QR Code
&et=6FD48CA0A0DD475943DD15421430A7E9C8F8769885EBF162C1FCA880F9D02ECBFCAF5202BE73811738733EEFAA46885E68CDC1CAA92B5EAF636B92888B3130E58157ACA43AE0AB1709E8D34ACFA578BDF3073058C5555B450A5442E4CD7C7F8A5263192DEAEDDCCAD55DA810678C2AF86E4A6907F326AE054A7A508E1A7636722B3DF154638AC211&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9F915C6F01DE79C5&aid=1B4F2A2B6C1A4B2A584154779F627A60&vid=&iid=59906B3B2830C2C5&sid=8637B749179B02B3&eid=DE4E739E935BD9A7&fileno=20161207&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9F915C6F01DE79C5"; var my_aid="1B4F2A2B6C1A4B2A584154779F627A60";