Jiang Yuliang,Li Bin,Ji Zhe,et al.Analysis of position errors of 3D printing individual non-coplanar template for radioactive seed implantation for malignant tumor[J].Chinese Journal of Radiological Medicine and Protection,2016,36(12):913-916 |
Analysis of position errors of 3D printing individual non-coplanar template for radioactive seed implantation for malignant tumor |
Received:June 14, 2016 |
DOI:10.3760/cma.j.issn.0254-5098.2016.12.007 |
KeyWords:3D printing Template Radioactive seed implantation Errors |
FundProject:首都临床特色应用研究与成果推广项目(Z151100004015171) |
Author Name | Affiliation | E-mail | Jiang Yuliang | Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China | | Li Bin | Department of Radiation Oncology, Luoyang Gentral Hospital Affiliated to Zhengzhou University, Luoyang 471000, China | | Ji Zhe | Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China | | Guo Fuxin | Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China | | Sun Haitao | Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China | | Fan Jinghong | Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China | | Li Xu | Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China | | Zhang Lujing | Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China | | Wang Junjie | Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China | junjiewang_edu@sina.cn |
|
Hits: 5146 |
Download times: 2790 |
Abstract:: |
Objective To investigate the accuracy and errors of 3D printing individual non-coplanar template (3D printing template) for 125I seed implantation in head and neck, thoracic and pelvic recurrent carcinoma.Methods From 2015 to 2016, a total of 41 patients treated with 125I seed implantation under 3D printing template were analyzed. All of them were conducted with CT-simulator scan two days before operation. The x and y axis position errors of 3D printing template between pre- and intro-operation plan, and set-up error in different site and position were analyzed. Results The x and y axis 3D individual non-coplanar template set-up position errors in head and neck, thoracic and pelvic location were (1.77±1.09), (2.66±1.65), (4.00±1.41), (5.22±1.85), (1.88±1.29) and (2.52±1.37) mm, respectively. Compared with thoracic, statistically significant difference was found in the head and neck and pelvic in x and y axis position errors (t=-3.730, -3.080, -3.944, -4.519, P<0.05). No statistically significant difference was observed in other results (P<0.05). Conclusions 3D printing individual non-coplanar template assistant I-125 seed implantation are more accurate and efficiency. |
HTML View Full Text View/Add Comment Download reader |
Close |
|
|
|