He Bin,Guo Ying,Yang Ruijing,Liu Hongming,Wang Pengcheng.Application of adaptive statistical iterative reconstruction in low dose temporal bone CT scan of children[J].Chinese Journal of Radiological Medicine and Protection,2016,36(7):544-547
Application of adaptive statistical iterative reconstruction in low dose temporal bone CT scan of children
Received:February 04, 2016  
DOI:10.3760/cma.j.issn.0254-5098.2016.07.014
KeyWords:Children  Temporal bone  Radiation dose  Evaluation research
FundProject:
Author NameAffiliationE-mail
He Bin Key Laboratory of Medical Imaging of Neurological Disease of Henan Province, Henan Provincial People's Hospetal, Zhengzhou 450003, China  
Guo Ying Key Laboratory of Medical Imaging of Neurological Disease of Henan Province, Henan Provincial People's Hospetal, Zhengzhou 450003, China  
Yang Ruijing Key Laboratory of Medical Imaging of Neurological Disease of Henan Province, Henan Provincial People's Hospetal, Zhengzhou 450003, China  
Liu Hongming Key Laboratory of Medical Imaging of Neurological Disease of Henan Province, Henan Provincial People's Hospetal, Zhengzhou 450003, China  
Wang Pengcheng Tai'an Taishan Medical University, Tai'an 271016, China wpc163@163.com 
Hits: 2792
Download times: 1907
Abstract::
      Objective To evaluate clinical use of adaptive statistical iterative reconstruction (ASiR) method in low-dose scan on children temporal bone by comparison of radiation dose delivered by GE Discovert HD CT 750 scan and GE Lightspeed VCT64 scan.Method Sixty patients with congenital deafness were divided into two groups according to gender, age (each N=30).Group a received low-dose CT scan on temporal bone by GE Discovery HDCT 750 (preset NI=12), and the original images were reconstructed with ASiR (weighted value=40%). Group B received CT scan by GE Lightspeed VCT 64 (preset NI=8), and the original images were reconstructed with filter back projection (FBP). Data were collected and analysed using the SPSS 18.0 software. Resultes The mean value of electric current of average tube and CTDIvol were significantly different between group A and B [(110.40±21.72) mA vs. (168.56±24.36) mA, and (26.43±3.48) mGy vs. (39.66±4.17) mGy, respectively (t=-9.76,-3.31,P<0.05)]. The noise index was (33.13±2.68) in group A and (33.79±2.93) in group B respectively, and the results had no statistical significance (P > 0.05). Subjective scores of the images were (4.06±0.03) and (4.05±0.03), with no statistical significance either (P > 0.05). ConclusionsOn a condition of achieving same image quality, CT scan program using GE Discovery HD CT 750 with 40% ASiR reconstruction and 4 units NI value enhancement could effectively reduce radiation dose on children's temporal bone compared to FBP method using GE Lightspeed VCT 64.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9079414  On-line:0

v
Scan QR Code
&et=DCA5CABA83612A94A5657E2362FE04B185ED9E865B5F810F0C9198B92F7C2CB396EC862837EFB9388624ADC6E8FFD3242685641A87C767D10F8CC73ABB68B94A8C3EA11201225006DEBC4949407F52AE5EE0B95FB0906CE80234A833D942422265CD1DD8A8777532B504EA7A742EA259&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9F915C6F01DE79C5&aid=65B039F9D05E9856B6FF09B2772185B7&vid=&iid=DF92D298D3FF1E6E&sid=B34BDD6A690A04C0&eid=4002B7787911C73B&fileno=20160714&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9F915C6F01DE79C5"; var my_aid="65B039F9D05E9856B6FF09B2772185B7";