Li Wenyan,Fan Yaohua,Huang Zhuo,et al.The measurements of eye lens dose for occupational staff in interventional procedures[J].Chinese Journal of Radiological Medicine and Protection,2016,36(4):303-307
The measurements of eye lens dose for occupational staff in interventional procedures
Received:January 15, 2016  
DOI:10.3760/cma.j.issn.0254-5098.2016.04.015
KeyWords:Interventional staff  Eye lens  Personal dose equivalent Hp(3)  Thermoluminescent dosimeter (TLD)  Optically stimulated luminescence dosimeter
FundProject:国家科技支撑计划(2014BAI12B04)
Author NameAffiliationE-mail
Li Wenyan Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Fan Yaohua Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China fyaohua1@sina.com 
Huang Zhuo Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Ou Xiangming Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Yue Baorong Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Xu Hui Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China  
Hits: 5266
Download times: 2785
Abstract::
      Objective To establish methods of measuring the eye lens dose to interventional staff, to obtain relevant dose data and to provide a scientific basis for reducing eye lens dose. Methods Two kinds of dosimeters, thermoluminescent dosimeter (TLD) and optically stimulated luminescence dosimeter (OSLD), were selected to measure the personal dose equivalent Hp(3) to eye lens of occupational staff in several kinds of interventional procedures, including cardiovascular interventional procedures, cerebrovascular interventional procedures etc. Five types of Digital Subtraction Angiography (DSA) equipment were chosen in the study, including single tube equipment and double tube equipment. Results The eye lens dose Hp(3) to interventional staff varied significantly with different interventional procedures. The lowest dose is shown in the coronary angiography procedure, while the highest dose shown in the cerebral stenting procedure. For the same type of interventional procedure, the eye lens dose to the primary interventionist was the highest. For same interventionist, the dose to the left eye was obviously higher than that to the right eye. In addition, the measured results of OSLD were apparently higher than that of TLD. Conclusions Both TLD and OSLD could be used to measure eye lens dose, and the ways of calibrating TLD to evaluate personal dose equivalent Hp(3) were feasible. The reason of significant difference between the measured results of TLD and OSLD needs further research.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11565301  On-line:0

v
Scan QR Code
&et=83E7D4990293BCDC18DF4DA962B15F3F7C0349086B470CE1C7F17B2E35BC882E59FB9D739DE506565FB8B99512451A18A122D1E1A5EC9673DB7ACBB27A0FE018931198B2F4EC4F525C553B9E536591E9A517161961B8B446&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9F915C6F01DE79C5&aid=28B2676AB082C1DCC8A846BA2F8F5184&vid=&iid=E158A972A605785F&sid=358F98408588E522&eid=F416A9924F23B020&fileno=20160415&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9F915C6F01DE79C5"; var my_aid="28B2676AB082C1DCC8A846BA2F8F5184";