Zhu Huayong,Pan Jingli,Zhu Weiping,Li Yangfei,Ding Jianrong,Fan Shufeng,Ji Wenbin.Effect of adaptive statistical iterative reconstruction algorithm on the imaging quality in low-dose spectral CT scanning of the liver[J].Chinese Journal of Radiological Medicine and Protection,2015,35(12):948-952
Effect of adaptive statistical iterative reconstruction algorithm on the imaging quality in low-dose spectral CT scanning of the liver
Received:May 27, 2015  
DOI:10.3760/cma.j.issn.0254-5098.2015.12.015
KeyWords:Liver  Spectral imaging  Adaptive statistical iterative reconstruction (ASIR)  Radiation dose  Tomography, X-ray computed
FundProject:浙江省医药卫生科技计划A类项目(2013KYA227)
Author NameAffiliationE-mail
Zhu Huayong Radiology Department, Taizhou Hospital of Zhejiang Province, Linhai 317000, China  
Pan Jingli Radiology Department, Taizhou Hospital of Zhejiang Province, Linhai 317000, China  
Zhu Weiping Radiology Department, Taizhou Hospital of Zhejiang Province, Linhai 317000, China  
Li Yangfei Radiology Department, Taizhou Hospital of Zhejiang Province, Linhai 317000, China  
Ding Jianrong Radiology Department, Taizhou Hospital of Zhejiang Province, Linhai 317000, China  
Fan Shufeng Radiology Department, Taizhou Hospital of Zhejiang Province, Linhai 317000, China  
Ji Wenbin Radiology Department, Taizhou Hospital of Zhejiang Province, Linhai 317000, China jwb_tzyy@126.com 
Hits: 3390
Download times: 2078
Abstract::
      Objective To investigate the value of the adaptive statistical iterative reconstruction (ASIR) algorithm for reducing the radiation dose and optimizing the image quality in the low-dose spectral CT scanning in GSI (Gemstone spectral imaging) of the liver. Methods A total of 60 patients who underwent hepatic spectral CT scanning in GSI were enrolled in this study. The patients were randomly divided into two groups according to priority with 30 cases per group. Low-dose spectral CT scanning was used for group A, and images were reconstructed by ASIR 0 and 50%, marked as A1 and A2. Group B was scanned with conventional dose of spectral CT, and images were reconstructed by Filtered back projection (FBP). Effective doses (E) for each group were calculated. Image quality was assessed by two radiologists, and the radiation doses were compared between groups A and B. Results All image quality of each group were good enough for clinical diagnosis. E for group A and B were (3.2±0.2) and (5.8±0.2) mSv, respectively. There was statistical difference with image noise between group A and B(Z=-6.784,P<0.05). The image noise, SNR and CNR had statistical differences between group A and B (F=24.013, 15.646, 8.285, P<0.05). Compared with group A1, the image noise was lower, and the SNR and CNR were higher in groups A2 and B(P<0.05). There were no statistical differences of image noise, SNR and CNR between groups A2 and B (P>0.05). There were no statistical differences of the image quality score between groups A1, A2 and B (F=102.38,105.768,P0.05). Conclusions ASIR combined with low-dose spectral CT scanning was helpful to reduce radiation dose and could obtain better image quality in hepatic CT examination.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9079431  On-line:0

v
Scan QR Code
&et=FF4EC6B96077DFE7AC7BEF4F943D76EB9D34E32048FF1D14BF3FA40DBEB729DF39DBA6A5099BA3474F935B95E25007AEC5E4961DF8452118F754522C7B6DA0B7D8C46CFD11D82C18B994AF4153EF894B82BB7FC2DEB12C10CB33A55F7CF5612855D0FF351C9738B9F2A68C2D23978B31A1C1EFE09469A291CC3364D86EDFAFD8E52534C0D0FA78E8&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FFD10F7019FAA9EC&aid=66A5F5CACC9A162378AF7AFC03CDD710&vid=&iid=59906B3B2830C2C5&sid=29C36F017AD88B64&eid=793F041A4288469A&fileno=20151216&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FFD10F7019FAA9EC"; var my_aid="66A5F5CACC9A162378AF7AFC03CDD710";