Yue Yao,Liu Haisheng,Wang Junjie,Guo Chengxiang,Jiang Yuliang,Sun Haitao.Monitoring of radiation dose to medical staff during 125I seeds loading[J].Chinese Journal of Radiological Medicine and Protection,2015,35(7):536-538
Monitoring of radiation dose to medical staff during 125I seeds loading
Received:December 15, 2014  
DOI:10.3760/cma.j.issn.0254-5098.2015.07.013
KeyWords:125I seeds  Thermoluminescence dosimeter  Dose surveillance
FundProject:首都医学发展科研基金(2009-2024)
Author NameAffiliationE-mail
Yue Yao Center of Oncology, Peking University Third Hospital, Beijing 100191, China  
Liu Haisheng 清华大学核能与新能源技术研究院  
Wang Junjie Center of Oncology, Peking University Third Hospital, Beijing 100191, China junjiew920@sohu.com 
Guo Chengxiang 清华大学核能与新能源技术研究院  
Jiang Yuliang Center of Oncology, Peking University Third Hospital, Beijing 100191, China  
Sun Haitao Center of Oncology, Peking University Third Hospital, Beijing 100191, China  
Hits: 2902
Download times: 2646
Abstract::
      Objective To analyze the dose of radiation to medical staff during 125I seeds loading Methods The radiation dose at different distances was measured by using thermoluminescence dosimeters (TLD), and the safe range for medical person was calculated. The doses and annual accumualive doses to the medical staff were estimated. Results The dose attenuation rates were 77.61%, 98.04%, 98.79%, 99.30%, 99.71% and 100% at distance of 10, 20, 30, 40, 50 and 100 cm from seeds tank, respectively. The dose to fingertips, chest, lens and thyroid of doctor were 51.08, 35.50,34.73 and 33.78 μGy, and the annual dose reached 12.77, 8.88, 8.68 and 8.45 mGy when the number of annual operations was 250. The attenuation rate was 79.60% and 28.36% of inside and outside lead glass, respectively. Conclusions The radiation is undetectable at 100 cm away from seeds tank in the process of loading of 125I seeds, and lead glass is necessary for radiation protection.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9066983  On-line:0

v
Scan QR Code
&et=3CBA26923B150914D66C064DF0EE36D7A10BC8189E779C185D7C7A9A26649351B11971D8DA61247CB1A3892D68FCBBA98CD8DFB24B66A76C10026A7C94A5DF2FD4F301C3AFFC4D686117E5C3CD50DE5E13A08BEF3ADA5662&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FFD10F7019FAA9EC&aid=1860F2A1EC277188399E210BB8A12FAA&vid=&iid=DF92D298D3FF1E6E&sid=323E8A365B085E0B&eid=E49BED2EA9A8956B&fileno=20150713&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FFD10F7019FAA9EC"; var my_aid="1860F2A1EC277188399E210BB8A12FAA";