Wu Huizhao,Wu Wenjuan,Song Yan,et al.Low-dose radiation in the hip digital tomosynthesis[J].Chinese Journal of Radiological Medicine and Protection,2015,35(2):153-156 |
Low-dose radiation in the hip digital tomosynthesis |
Received:November 11, 2013 |
DOI:10.3760/cma.j.issn.0254-5098.2015.02.019 |
KeyWords:Hip Digital tomosynthesis Radiation dose |
FundProject: |
Author Name | Affiliation | E-mail | Wu Huizhao | Department of Radiology, Third Affiliated Hospital of Hebei Medical University, Hebei Province Biomechanical Key Laboratory of Orthopedics, Shijiazhuang 050051, China | | Wu Wenjuan | Department of Radiology, Third Affiliated Hospital of Hebei Medical University, Hebei Province Biomechanical Key Laboratory of Orthopedics, Shijiazhuang 050051, China | wenjwu@163.com | Song Yan | Department of Radiology, Third Affiliated Hospital of Hebei Medical University, Hebei Province Biomechanical Key Laboratory of Orthopedics, Shijiazhuang 050051, China | | Lu Junli | Department of Radiology, Third Affiliated Hospital of Hebei Medical University, Hebei Province Biomechanical Key Laboratory of Orthopedics, Shijiazhuang 050051, China | | Guo Zhe | Department of Radiology, Third Affiliated Hospital of Hebei Medical University, Hebei Province Biomechanical Key Laboratory of Orthopedics, Shijiazhuang 050051, China | | Zhang Zekun | Department of Radiology, Third Affiliated Hospital of Hebei Medical University, Hebei Province Biomechanical Key Laboratory of Orthopedics, Shijiazhuang 050051, China | |
|
Hits: 4533 |
Download times: 3072 |
Abstract:: |
Objective To explore the optimal dose ratio set in the hip digital tomosynthesis(DTS), and to reduce patient's examination dose as low as possible.Methods Ninety patients who received hip DTS examination were randomly divided into 3 groups, with the dose ratio as 6, 7 and 8, respectively. One-way ANOVA test was used to compare the image quality and radiation dose among 3 groups.Results The values of entrance surface dose (ESD), dose-area product (DAP) and image quality score of 3 groups were [(3.76±1.89)mGy, (18.41±11.71)dGy ·cm2, 3.03±0.24], [(5.24±2.76)mGy, (26.99±13.34)dGy ·cm2), 3.60±0.11], and [(6.39±1.75)mGy, (36.96±22.49)dGy ·cm2, 3.64±0.09], respectively. The difference among three groups was statistically significant (F=10.94,9.45,139.26, P<0.05).The S-N-K test showed that both ESD values and DAP values in 6,7,and 8 time-dose ratio group was from small to large. The image quality score of 6 time-dose ratio group was lower than that of the other groups with no significant difference.Conclusions Dose ratio is one of the important parameters to result in the radiation dose of DTS. Dose ration 7 is optimal in hip DTS, which could match the image quality and radiation dose best and finally protect patients from unnecessary radiation damage. |
HTML View Full Text View/Add Comment Download reader |
Close |
|
|
|