Hu Panpan,Zhuo Weihai,Kong Yan,Chen Bo,Liu Haikuan,Yi Yanling.Shielding effect of lead glasses on eye lens exposure in interventional radiologists[J].Chinese Journal of Radiological Medicine and Protection,2014,34(12):927-930
Shielding effect of lead glasses on eye lens exposure in interventional radiologists
Received:July 07, 2014  
DOI:10.3760/cma.j.issn.0254-5098.2014.12.014
KeyWords:Lead glasses  Interventional radiology  Eye lens  Dose  Monte Carlo simulation methods
FundProject:国家自然科学基金(11075040)
Author NameAffiliationE-mail
Hu Panpan Institute of Radiation Medicine, Fudan University, Shanghai 200032, China  
Zhuo Weihai Institute of Radiation Medicine, Fudan University, Shanghai 200032, China whzhuo@fudan.edu.cn 
Kong Yan Institute of Radiation Medicine, Fudan University, Shanghai 200032, China  
Chen Bo Institute of Radiation Medicine, Fudan University, Shanghai 200032, China  
Liu Haikuan Institute of Radiation Medicine, Fudan University, Shanghai 200032, China  
Yi Yanling Institute of Radiation Medicine, Fudan University, Shanghai 200032, China  
Hits: 3628
Download times: 2645
Abstract::
      Objective To study the shielding effect of equivalent thickness and size of lead glasses on eye lens of interventional radiologists. Methods Based on the human voxel phantom and MCNPX software,doses to eye lens of radiologists were simulated under different conditions of wearing lead glasses and beam projections, and measurements were performed with anthropomorphic phantom placed with eye lens dosimeters to verify simulation results. Results The results showed that the dose to eye lens reduced by a factor from 3 to 9 when the equivalent thickness of glasses ranged from 0.1 to 1.0 mm Pb with a len size of 20 cm2. The dose reduction factors (DRF) not only depended on the lead equivalent, but also on the beam projection of X-rays. However, the increase in DRF was not significant whenever the lead equivalent of glasses was larger than 0.35 mm. Furthermore, the DRF was proportional to the size of glass lens from 6 to 30 cm2 with the same lead equivalent. The simulation results were in well agreement with the measured ones. Conclusions For more reasonable and effective protection of the eye lens of interventional radiologists, a pair of glasses with a lead equivalent of 0.5 mm and large-sized lens is recommended.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9080534  On-line:0

v
Scan QR Code
&et=79DC92D373DF3A73B6F528D92C7D871DEE3F884DD295739431B45994AF3F4ED998DCC3C4BC81C790843AEF9A95A7570B6C6CD80A275338176E2211EF981B8F55ACC095E8C3E8FBEFF7D3AA5570EFECE45063FF27F024C811&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9EAD63ADE6B277ED&aid=A99B6360A1E419EEF7EC8AE107F5E895&vid=&iid=59906B3B2830C2C5&sid=8B6586F75D2B256A&eid=8587C7CAA7A3D0DB&fileno=20141214&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9EAD63ADE6B277ED"; var my_aid="A99B6360A1E419EEF7EC8AE107F5E895";