Deng Chong,Lin Qin,Shi Liwan,et al.The suitable uptake value threshold of 18F-FDG PET/CT image on gross tumor volume delineation of nasopharyngeal carcinoma[J].Chinese Journal of Radiological Medicine and Protection,2014,34(7):530-534
The suitable uptake value threshold of 18F-FDG PET/CT image on gross tumor volume delineation of nasopharyngeal carcinoma
Received:November 07, 2013  
DOI:10.3760/cma.j.issn.0254-5098.2014.07.013
KeyWords:18FDG PET/CT  Nasopharyngeal carcinoma  Gross tumor volume  Delineation
FundProject:
Author NameAffiliationE-mail
Deng Chong Department of Radiation Oncology, Cancer Center of First Affiliated Hospital of Xiamen University, Xiamen 361003, China  
Lin Qin Department of Radiation Oncology, Cancer Center of First Affiliated Hospital of Xiamen University, Xiamen 361003, China  
Shi Liwan Department of Radiation Oncology, Cancer Center of First Affiliated Hospital of Xiamen University, Xiamen 361003, China  
Zhu Luchao Department of Radiation Oncology, Cancer Center of First Affiliated Hospital of Xiamen University, Xiamen 361003, China  
Tian Ye 苏州大学附属第二医院放疗科 dryetian@hotmail.com 
Hits: 4411
Download times: 2139
Abstract::
      Objective To define a suitable threshold setting for gross tumor volume (GTV)when using 18F-fluoro-deoxyglucose positron emission tomography and computed tomogram (PET/CT) for radiotherapy planning in Nasopharyngeal carcinoma(NPC).Methods Sixteen NPC patients respectively received PET/CT and MRI scan before their radiation treatment. All of the images were transferred to the radiotherapy planning system (TPS). MRI/CT-based primary GTV was defined as GTVf. Biological target volumes (BTVs) were derived from PET/CT-based GTVs of primary tumors. The BTVs were defined as the volumes when adjusting different percentage of the maximal standardized uptake value (SUVmax). GTVfs were compared with BTVs. The suitable threshold level (sTL) could be determined when BTV value and its morphology using a certain threshold level were observed to be the fittest GTVf. The suitable standardized uptake value (sSUV) was calculated as the sTL multiplied by the SUVmax. Results Our result demonstrated no single sTL or sSUV method could achieve an optimized volumetric match with the GTVf. The sTL was[20.93%±6.51%(15%-40%)], whereas the sSUV was[2.27±0.48(1.56-3.25)]. The sTL was inversely correlated with the SUVmax , sTL=-0.144ln(SUVmax)+0.5548(R2=0.85,F=78.57, P<0.01. The sSUV showed a linear correlation with the SUVmax,sSUV=0.104(SUVmax)+ 1.0398,(R2=0.75,F=41.88,P<0.01). The sTL was not associated with the value of GTVf. Conclusions In PET/CT-based BTV for NPC, SUVmax threshold method is feasible. sTL is not a fixed value, which is correlated with the SUVmax instead of the value of tumor.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11565987  On-line:0

v
Scan QR Code
&et=9F96D6BCBBA96C3A48D4BE112D636150BC904E2B766E2E0604B97AD2F86297EF5FA6356AC93287E826ED18EC9F532CDB096F1D89376D9355A60F27FE60C9DFD52E78C5773D40B9D42AACEAA9BD85E67C8D1DBB6D2BD13B15481EB86BBE3F11EC4289AEFBCC9CD6873B4ECC3522F249A38617400A77E588BADBED5E1FAA09B96977E77540BA4D1B72&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9EAD63ADE6B277ED&aid=0430BD2A3227970BFFBA3AB37FDC26D3&vid=&iid=DF92D298D3FF1E6E&sid=BB98BB04E861B6F5&eid=D45762219109E903&fileno=20140713&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9EAD63ADE6B277ED"; var my_aid="0430BD2A3227970BFFBA3AB37FDC26D3";