Guo Senlin,Niu Yantao.Application of iterative algorithm in paranasal sinus MSCT[J].Chinese Journal of Radiological Medicine and Protection,2014,34(5):390-393
Application of iterative algorithm in paranasal sinus MSCT
Received:May 27, 2013  
DOI:10.3760/cma.j.issn.0254-5098.2014.05.019
KeyWords:Paranasal sinus  Tomography, X-ray computed  Iterative reconstruction  Radiation dose
FundProject:
Author NameAffiliationE-mail
Guo Senlin Department of Radiology, Beijing Tongren Hospital, Capital Medical University, 100038 Beijing, China  
Niu Yantao Department of Radiology, Beijing Tongren Hospital, Capital Medical University, 100038 Beijing, China ytniu163@163.com 
Hits: 3180
Download times: 2132
Abstract::
      Objective To study the effect of iterative algorithm (iDose algorithm) on image quality and radiation dose in paranasal sinus MSCT.Methods A proper cadaveric head based on the average CNR (contrast noise ratio) of paranasal sinus images in 53 patients was applied.The cadaveric head was scanned with different parameters of kV and effective mAs.The images were reconstructed with filtered back projection and iterative algorithm (iDose 1-7) respectively.The subjective and objective evaluations were performed for all the images and the optimal parameter combination was found out.Results The CNR of coronal images was slightly higher than that of axial images (t=-6.86, P<0.05).The image CNR of protocol (120 kV,100 mAs/slice and iDose5) was close to that of conventional protocol.The protocol of 100 kV,60 mAs/slice and iDose4 offered the images adaptable for diagnosis of inflammation.The protocol of 100 kV, 80 mAs/slice and iDose4 offered the images adaptable for diagnosis of inflammation and fracture, and the radiation dose were reduced by 82% and 75%, respectively.Conclusions Using the iDose algorithm could help to offer diagnostic images for inflammation and fracture and reduce the radiation dose in the paranasal sinus MSCT.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9068158  On-line:0

v
Scan QR Code
&et=DCA5CABA83612A94527D8C68DFB10B6F6794B064DE9B713577B4E50BD32B63C6473EBFEFBECFF0E0A34179D19C15B77E4C757FDB80F3D9ED2BC03655808D5E41&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9EAD63ADE6B277ED&aid=3CC66326E61FC91B48347E99005DD718&vid=&iid=94C357A881DFC066&sid=A22854835F81B3F8&eid=23F20F9780C3579E&fileno=20140519&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9EAD63ADE6B277ED"; var my_aid="3CC66326E61FC91B48347E99005DD718";