Gu Jianhua,Lu Xiuliang,Zhuo Weihai,Fan Dunhuang.Methods and effects of abdominal and pelvic shielding for pediatric chest CT examinations[J].Chinese Journal of Radiological Medicine and Protection,2014,34(4):298-301
Methods and effects of abdominal and pelvic shielding for pediatric chest CT examinations
Received:September 04, 2013  
DOI:10.3760/cma.j.issn.0254-5098.2014.04.016
KeyWords:Chest CT scans  Gonad  Colon  Shielding effects
FundProject:国家自然科学基金(11075040);上海市公共卫生优秀学科带头人培养计划(GWDTR201206)
Author NameAffiliationE-mail
Gu Jianhua Institute of Radiation Medicine, Fudan University, Shanghai 200032, China  
Lu Xiuliang 复旦大学附属中山医院  
Zhuo Weihai Institute of Radiation Medicine, Fudan University, Shanghai 200032, China whzhuo@fudan.edu.cn 
Fan Dunhuang Institute of Radiation Medicine, Fudan University, Shanghai 200032, China  
Hits: 3036
Download times: 3212
Abstract::
      Objective To investigate the methods and effects of abdominal and pelvic shielding for pediatric chest CT examinations. Methods The 705-D phantom made by Computerized Imaging Reference Systems (CIRS) was used to replace a 5-year-old child, thermoluminescent dosimeters were set in the abdomen and pelvis to measure the organ and tissue doses. Chest scans were conducted with the routine protocol for pediatric chest CT examinations. Doses to main organs and tissues in the abdomen and pelvis were measured after chest CT scans without lead apron, with lead apron covering anterior of the abdomen and pelvis and with apron wrapping same part, respectively.Results Absorbed doses to some abdominal organs near the irradiation field were up to several mGy in a procedure of pediatric chest CT examination. There were statistically significant differences among the dose values for three different scans at the same location (χ2=16.00,P<0.05). Statistically significant difference was also found between the dose values for scans, which were measured with wrapping and covering approaches (Z=-2.52,P<0.05). Compared to the doses in the condition of no shielding, the doses in testis and colon reduced by 71.2% and 42.3%, respectively, if the abdomen and pelvis was wrapped with a lead apron (0.35 mm Pb), and reduced by 55.9% and 26.1%, respectively, if the same lead apron was used to cover the anterior of the abdomen and pelvis. Conclusions In pediatric chest CT examinations, the use of a lead apron can effectively shield the abdomen and pelvis, and plays an important role in protection of the gonad and colon. The wrapping measure is worth being recommended.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9059849  On-line:0

v
Scan QR Code
&et=CD0D5BDE41AE57DB82AEF90A8A79A0E723D18340DD814E3F0E40FC3A8E1EE183A47D8CCABAC57BF151A6C2D8F6C5435E32AF56200BCFD83931FE34B4A5E12399ABEB3095B1DF6424FAE860321711D4B228415F1614F637CC73A766F17BFBFCEA&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9EAD63ADE6B277ED&aid=6254F803FD8F6343FC8771A49D7FCAE4&vid=&iid=E158A972A605785F&sid=88D36036CFF69B3C&eid=DFEE4E8C33C95CEF&fileno=20140416&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9EAD63ADE6B277ED"; var my_aid="6254F803FD8F6343FC8771A49D7FCAE4";