Wang Wei,Li Jianbin,Ma Zhifang,et al.Assessment of inter-fractional displacement during the breast intensity modulated radiotherapy based on the on-line Cone Beam CT corrections[J].Chinese Journal of Radiological Medicine and Protection,2014,34(3):192-195
Assessment of inter-fractional displacement during the breast intensity modulated radiotherapy based on the on-line Cone Beam CT corrections
Received:May 31, 2013  
DOI:10.3760/cma.j.issn.0254-5098.2014.03.009
KeyWords:Whole breast intensity modulated radiotherapy  Inter-fractional displacement  CBCT  Setup error  Adaptive radiotherapy
FundProject:山东省医药卫生科技发展计划项目(2013WS0346);山东省科技发展计划项目(2012YD18084)
Author NameAffiliationE-mail
Wang Wei Department of Radiation Oncology, Shandong Cancer Hospital & Institute, Jinan 250117, China  
Li Jianbin Department of Radiation Oncology, Shandong Cancer Hospital & Institute, Jinan 250117, China lijianbin@msn.com 
Ma Zhifang Department of Radiation Oncology, Shandong Cancer Hospital & Institute, Jinan 250117, China  
Fan Tingyong Department of Radiation Oncology, Shandong Cancer Hospital & Institute, Jinan 250117, China  
Shao Qian Department of Radiation Oncology, Shandong Cancer Hospital & Institute, Jinan 250117, China  
Xu Min Department of Radiation Oncology, Shandong Cancer Hospital & Institute, Jinan 250117, China  
Xing Jun Department of Radiation Oncology, Shandong Cancer Hospital & Institute, Jinan 250117, China  
Zhang Yingjie Department of Radiation Oncology, Shandong Cancer Hospital & Institute, Jinan 250117, China  
Hu Hongguang IGRT技术组  
Hits: 4372
Download times: 3315
Abstract::
      Objective To explore the inter-fractional geometric uncertainties in breast cancer patients receiving intensity modulated radiotherapy (IMRT) using cone beam CT (CBCT), and to quantify the inter-fractional motion of breast cancer patients. Methods Eighteen breast cancer patients were included in this study, who had received whole breast IMRT after breast conserving surgery. A total of 452 CBCT scans were acquired. Three dimensional inter-fractional motion and setup errors before and after on-line CBCT-based corrections were quantitatively analyzed. The magnitude trends of inter-fractional motion during the treatment were also assessed. Results The magnitudes of the inter-fractional displacements varied among the 18 patients. For the same patient, the disparities in three directions were also different. The maximum inter-fractional variability prior to CBCT-based corrections in the lateral (LR),anteroposterior (AP) and superoinferior (SI) directions were 0.22,0.49 and 0.48 cm respectively, while 0.16, 0.21 and 0.17 cm respectively after on-line CBCT-based corrections. On-line CBCT-based corrections decreased the displacement in SI direction (-0.08 cm vs 0.03 cm, t=-2.373, P<0.05) and random error(t=5.302, 6.689, 4.812,P<0.05), but there were no significant differences for systematic errors. No trends in inter-fractional motion before and after on-line CBCT-based corrections were observed. Conclusions For breast cancer patients who received IMRT, both inter-fractional displacement in SI direction and mean population random errors in three dimensions were reduced after on-line CBCT-based corrections using automatic greyscale match. As a result of individual differences, no significant trend of inter-fractional displacement was identified.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11565766  On-line:0

v
Scan QR Code
&et=EB1E2AC52F4404793466D2679EE62D0C15283E677134F9FBE5B87651C6CF46243417FA93D49F56A09686F63336889C502CF232C61300D857985E472780A7F4DD75FE3DB5A5BE16080925C151960094E8D5B8D1A2A9BE797A894BF5A250A7A863D770C5D100C5FAF97D618DDE5980A9B1D6691E9BB187F919D25015124C428443B8BE5B491CEF5D5CD0541BE99671EB34&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9EAD63ADE6B277ED&aid=902666A849768A319C20DDBBABB8BD72&vid=&iid=38B194292C032A66&sid=C29816B2656377A7&eid=64963996248CBF47&fileno=20140309&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9EAD63ADE6B277ED"; var my_aid="902666A849768A319C20DDBBABB8BD72";