Hou Dongliang,Fang Tong,Liu Hui,et al.Application of CT/MR image fusing in gross tumor volume delineation of esophageal squamous cell carcinoma[J].Chinese Journal of Radiological Medicine and Protection,2014,34(2):129-132
Application of CT/MR image fusing in gross tumor volume delineation of esophageal squamous cell carcinoma
Received:May 27, 2013  
DOI:10.3760/cma.j.issn.0254-5098.2014.02.013
KeyWords:Target delineation  Esophageal neoplasm  Diffusion-weighted magnetic resonance imaging  Image fusion
FundProject:
Author NameAffiliationE-mail
Hou Dongliang Beijing Shijitan Hospital, Capital Medical University, Beijing 100038, China  
Fang Tong Beijing Shijitan Hospital, Capital Medical University, Beijing 100038, China fangt369@163.com 
Liu Hui 河北医科大学第四医院影像科  
Wang Yaning 河北医科大学第四医院影像科  
Liu Bo Beijing Shijitan Hospital, Capital Medical University, Beijing 100038, China  
Hits: 3811
Download times: 2205
Abstract::
      Objective To investigate the application value of CT/MR image fusing in gross tumor volume (GTV) delineation of esophageal squamous cell carcinoma. Methods Twenty-nine patients with esophageal squamous cell carcinoma to be treated with radical surgery underwent routine CT scanning, MR T2-weighted imaging (T2WI) and diffusion weighted imaging(DWI)before surgery. Diffusion-sensitive gradient b values were taken at 400, 600, and 800 s/mm2. GTVs were delineated on the CT image, CT/MR T2WI, and CT/MR DWI respectively. The MR T2W1 image was used as the intermediary for the fusion of the CT image and MR DWI image. The length of GTVs measured under different imaging conditions were compared with the length of the resected specimen of esophagus. Results The GTV length was (44.94±18.46) and (45.05±21.47) mm on the CT images and CT/MR T2WI images respectively. When the b values were 400, 600, and 800 s/mm2, the esophageal carcinoma GTV length on CT/MR DWI images was (42.12±17.79), (41.18±17.17) and (39.77±17.66) mm, respectively. The coefficient between the esophageal carcinoma GTV lengths on CT/MR DWI images and the pathological lesion lengths was 0.928, 0.926 and 0.927 respectively. Conclusions CT/MR DWI images displays esophageal carcinoma GTV length more accurately, thus guiding the delineation of GTV effectively.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11566167  On-line:0

v
Scan QR Code
&et=DCA5CABA83612A949830E4D5A38BF085454A5660CB4BB7A48E07BB7A244EAD17BDB4109D20572514D38EAEE3D0F477464D94B91F1DA2B91120DAB486C1FA98DDCC7278A180CAD4C06BFCB86B8D8673FBC8E1275D6A5F0128AFC110E808DA1474B457D17BB19EF981173428D7167518F0&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9EAD63ADE6B277ED&aid=85AF3EE9C4B7D04213D54470359B17D2&vid=&iid=0B39A22176CE99FB&sid=28F8B56DB6BEE30E&eid=7C72DBC13F2D71EC&fileno=20140213&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9EAD63ADE6B277ED"; var my_aid="85AF3EE9C4B7D04213D54470359B17D2";