Min Xuanyu,Zhang Xiaohong,Lou Zhichao,Zhang Yanan,Hu Xiaodan,Zhang Haiqian.Development of a new biodosimetry based on serum copper in γ-ray irradiated mice[J].Chinese Journal of Radiological Medicine and Protection,2014,34(2):99-102
Development of a new biodosimetry based on serum copper in γ-ray irradiated mice
Received:June 28, 2013  
DOI:10.3760/cma.j.issn.0254-5098.2014.02.006
KeyWords:Biological dosimeter  Serum copper  γ-rays  Mice
FundProject:江苏省自然科学基金(BK20131355);江苏省研究生教育创新资助项目(CXLX12-0145)
Author NameAffiliationE-mail
Min Xuanyu Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China  
Zhang Xiaohong Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China  
Lou Zhichao Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China  
Zhang Yanan Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China  
Hu Xiaodan Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China  
Zhang Haiqian Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China zhanghq@nuaa.edu.cn 
Hits: 2750
Download times: 1986
Abstract::
      Objective To investigate the changes of serum copper in mice after whole-body irradiation and analyze the feasibility of these changes as a biological dosimeter. Methods Serum copper in mice exposed to 60Co γ-rays(0,1,2,3,5 Gy) was collected from the orbital of mice and detected with 5-Br-PADAP colorimetric method at 30 min and 7 d after radiation. One-way analysis of variance was used to analyze the difference of serum copper in each group and Dunnett-t test was used to compare the difference between control group and irradiated groups. Linear and quadratic linear fitting function was used to analyze the relationship between serum copper and radiation dose. The change of serum copper was detected at 30 min, 1, 3, 5, 7, 10, 13 and 16 d after radiation to observe the persistence of serum copper. The established relationships were used to estimate the dose in 8 mice irradiated by a blind dose.ResultsThe amount of serum copper in irradiated mice were significantly (F=208.20,145.98,P<0.05) dependent on the radiation doses with dose responses of y=-0.091x+0.936 and y=-0.011x2-0.032x+0.962 (r=0.989, 0.995) at 30 min and 7 d post-irradiation, respectively. The concentration of serum copper at 2.0 Gy decreased at 30 min post-irradiation, increased at 1-7 d, then kept at a stable level at 7-14 d even increased slightly after 14 d. With these dose response curves, after radiation with a blind dose of 2 Gy, the absorb doses of mice were assessed to be (1.83-2.25) Gy and (1.82-2.11)Gy at 30 min and 7 d in 95% confidence interval, respectively. Conclusions The serum copper is a quick, simple, and sensitive biomarker for the early assessment of absorb dose of irradiated mice.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9069289  On-line:0

v
Scan QR Code
&et=A90EAC7419FB9B220C8CA3675965BF0D0A15CCED4A97C5B4F6B950C10EADB89FD242D7E24DDBAC38AD3D96F9D37226F96060BCDCC3AFC6310E3B5BAD1DC7EF24BB13A2C6B2AAD309776FF1DF0539A81A009A2D850896102B&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9EAD63ADE6B277ED&aid=0999E3A37C445912B99E836677891075&vid=&iid=0B39A22176CE99FB&sid=A4FA325EA800C820&eid=331211A5F5616413&fileno=20140206&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9EAD63ADE6B277ED"; var my_aid="0999E3A37C445912B99E836677891075";