Zhao Nan,Yang Ruijie*,Wang Junjie.Customized planning for radioactive 125I seed implantation[J].Chinese Journal of Radiological Medicine and Protection,2014,34(1):54-58
Customized planning for radioactive 125I seed implantation
Received:March 16, 2013  
DOI:10.3760/cma.j.issn.0254-5098.2014.01.015
KeyWords:125I  Radioactive seeds  Seeds implant  Treatment planning  Customized planning
FundProject:国家自然科学基金(81372420,81071834);首都医学发展科研基金(2009-2024)
Author NameAffiliationE-mail
Zhao Nan Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Yang Ruijie* Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China ruijyang@yahoo.com 
Wang Junjie Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China  
Hits: 3910
Download times: 2079
Abstract::
      Objective To customize the optimal plans for radioactive 125I seeds volumetric implants in selected regular target volumes. Methods 125I seeds were symmetrically and uniformly implanted into 3 spherical targets with the diameters of 1, 2 and 3 cm and 7 ellipsoidal targets with the 3 dimensions of 1 cm×1 cm×2 cm, 1 cm×1 cm×3 cm, 1 cm×2 cm×2 cm, 1 cm×2 cm×3 cm, 1 cm×3 cm×3 cm, 2 cm×2 cm×3 cm and 2 cm×3 cm×3 cm. The activity and inter-space of seeds were adjusted to obtain the conformal and uniform dose distribution, with the prescribed D90 (the dose delivered to 90% of the targets) greater than 145 Gy. The inter-space of seeds was changed from 1 cm to 0.75 cm, to improve the conformity and uniformity of dose distribution. Plan quality was assessed using homogeneity index (HI), external index (EI) and conformal index (CI). The activity and number of seeds implanted were also recorded and compared. Results For the spherical target with the diameter of 1 cm, when seeds were implanted with the inter-space of 1 cm and 0.75 cm, the HI were 40.0% and 55.9%, the EI were 98.3% and 95.1%, the CI were 0.44 and 0.44, respectively. For the spherical target with the diameter of 3 cm and the target with the 3 dimensions of 1 cm × 2 cm× 2 cm, the implant with the inter-space of 1 cm provided better indices of HI, EI and CI than those with the inter-space of 0.75 cm. For the other targets, the implants with the inter-space of 0.75 cm provided better indices of EI and CI than those with the inter-space of 1 cm, although they displayed a little worse homogeneity in terms of HI. The activity per seed was 17.0-27.8 MBq and 30.0-58.8 MBq in the implants with the inter-spaces of 0.75 cm and 1 cm, respectively. 2-10 more seeds were needed in the implants with the inter-space of 0.75 cm. Conclusions For the studied targets except the spherical targets with the diameter of 1 cm and 3 cm and the ellipsoidal target with the dimension of 1 cm×2 cm×2 cm, 125I seeds implanted with the inter-space of 0.75 cm could provide more conformal dose distribution. It could be the better customized plans for uniformly spaced seed implantation.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9077684  On-line:0

v
Scan QR Code
&et=2D67478063A21C2F934775E0920288ACBF859D9E94C41A070691A53455C6B318880464926465DF1C484BE4E60BFD4F900D35050BA865DFAD2A2C7493BEF27BCE956E18BF4F3E7291&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9EAD63ADE6B277ED&aid=9D136FEB79ECE4DBC7EEE44A781DB337&vid=&iid=CA4FD0336C81A37A&sid=318E4CC20AED4940&eid=9FFCC7AF50CAEBF7&fileno=20140115&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9EAD63ADE6B277ED"; var my_aid="9D136FEB79ECE4DBC7EEE44A781DB337";