WANG Xiao-feng,SONG Pei-feng,XU Zhong-yang.Radiation protection shielding computation of gamma photons produced in positron annihilation[J].Chinese Journal of Radiological Medicine and Protection,2013,33(6):658-661
Radiation protection shielding computation of gamma photons produced in positron annihilation
Received:September 08, 2013  
DOI:10.3760/cma.j.issn.0254-5098.2013.06.025
KeyWords:Positron  Radiation protection calculating  18F  Tenth-value layers  PET
FundProject:
Author NameAffiliationE-mail
WANG Xiao-feng Nuclear and Radiation Safety Center, Ministry of Environmental Protection, Beijing 100082, China  
SONG Pei-feng Nuclear and Radiation Safety Center, Ministry of Environmental Protection, Beijing 100082, China  
XU Zhong-yang Nuclear and Radiation Safety Center, Ministry of Environmental Protection, Beijing 100082, China yibanxzy@sina.com 
Hits: 4033
Download times: 2595
Abstract::
      Objective To study the best method of radiation protection shielding calculation for the gamma photon produced in positron annihilation. Methods With 18F as the typical of nuclide, different methods or literature about constant and the calculation of the TVL or recommended values were adopted to calculate and analyze the shielding thickness by lead as block material. Results The shielding thickness by the dose constant was calculated by point source model (0.142 μSv·m2·MBq-1·h-1) and TVL of lead recommended by NCRP was the biggest: at the control area the unit thickness for lead shield was 7.562×10-4 mm·MBq-1 for one patient. While by the dose constant recommended by AAPM TG108 (0.092 μSv·m2·MBq-1·h-1) and lead TVL recommended by IAEA was the minimum. The unit thickness for lead shield at the control area was 4.982×10-4 mm·MBq-1·patient-1, with difference of 36.2%. Conclusions The dose constant and the TVL value of lead from AAPM. TG 108 are recommended for the calculation. In shielding design attention should be paid to the distance protection, the separate toilet with shielding for patients, and the separate corridors beteen doctors and patients.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11565577  On-line:0

v
Scan QR Code
&et=15C444C2D45CD59A83230A533437740160B7C1E7A685D326115721DE613CA983796729EBD926B3FA6540D90174782A2D18728278E92BB31EC0258BD921F762596A3DAF0E22611C5A0A0A235203BB5BA771A0FCAF437EBAF381944DA9A54E1659&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FF7AA908D58E97FA&aid=B1287D9B9CB36495C1F9289A24533114&vid=&iid=B31275AF3241DB2D&sid=4E8E6A5CE04FD382&eid=8DDBA6455F2E3ECF&fileno=20130631&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FF7AA908D58E97FA"; var my_aid="B1287D9B9CB36495C1F9289A24533114";