HU Liang,XIAO Sheng-xiang,XIAO Wen-bo,RUAN Ling-xiang.The comparison among image qualities of CTA at different dose in both lower extremity artery[J].Chinese Journal of Radiological Medicine and Protection,2013,33(4):442-444
The comparison among image qualities of CTA at different dose in both lower extremity artery
Received:May 21, 2013  
DOI:10.3760/cma.j.issn.0254-5098.2013.04.031
KeyWords:Lower extremity artery  CT angiography  Low-dose  Tomography
FundProject:
Author NameAffiliationE-mail
HU Liang Department of Clinical Medical Engineering, School of Medicine, Yiwu Affiliated Hospital, Zhejiang University, Hangzhou 310029, China  
XIAO Sheng-xiang 浙江大学医学院附属第一医院放射科 cn@139.com 
XIAO Wen-bo 浙江大学医学院附属第一医院放射科  
RUAN Ling-xiang 浙江大学医学院附属第一医院放射科  
Hits: 3167
Download times: 2915
Abstract::
      Objective To explore the differences among CT angiography(CTA) at different doses in both lower extremity arteries, and the relationship among volume rendering(VR) image quality, CT number and standard deviation(SD) value. Method CTA in lower extremity artery was performed in 90 patients. The participants were randomly divided into three groups, including a routine group (120 kV,150 mAs), 120 kV and 80 mAs group, and 100 kV and 130 mAs group with 30 cases in each group. The images were processed with VR and classified into three degrees, the first class, the second class and the third class, and VR image quality levels of three groups were compared. The receiver operating characteristic curve(ROC) was used to analyze the correlation among VR image quality level, CT number and SD value. Results The percentage of VR image level at the first class was 93.3% in the routine group, 86.6% in the 120 kV and 80 mAs group and 96.6% in the 100 kV and 130 mAs group. According to the correlation analysis between the SD value and VR image quality of CTA in lower extremity artery, the area under curve in ROC analysis was 0.9078. According to the correlation analysis between the CT number and VR image quality of CTA in lower extremity artery, the area under curve in ROC analysis was 0.9116. Conclusions The low-dose CAT in lower extremity artery is feasible. Application of 100 kV and 130 mAs could ensure better image quality.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9069205  On-line:0

v
Scan QR Code
&et=94824EDAD886E42669E5FDB9149ECCC94C0F739D911A4D28A6B15483166D025F74D152679A508E8C6D04489AE78BEA3E7661F9C42CEB9AC4CDDE1C5090286F5ED8496A3A1066116BBCC7D4BFE1749375852730C7D79740ACB66E02197B42C3EE&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FF7AA908D58E97FA&aid=CBE5FA4F89B0793693B4C1C84CE9A3CD&vid=&iid=E158A972A605785F&sid=D98387EFB283C5E0&eid=68FDAD96FCC0AB1B&fileno=20130431&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FF7AA908D58E97FA"; var my_aid="CBE5FA4F89B0793693B4C1C84CE9A3CD";