LI Qiang,QIAN Nong,LI Sheng,TONG Hong-zhang,XU Lie-fu,WANG Jian-hua.The application of dual-source CT in coronary angiography combined with right ventricular function analysis[J].Chinese Journal of Radiological Medicine and Protection,2013,33(4):438-441
The application of dual-source CT in coronary angiography combined with right ventricular function analysis
Received:December 03, 2012  
DOI:10.3760/cma.j.issn.0254-5098.2013.04.030
KeyWords:DSCT  Prospective ECG trigger  Coronary angiography  Right ventricular function  Radiation dose
FundProject:
Author NameAffiliationE-mail
LI Qiang Yinzhou Hospital Affiliated to Medical School of Ningbo University, Ningbo 315040, China  
QIAN Nong 南京医科大学附属常州二院放射科 qiannong007@163.com 
LI Sheng Yinzhou Hospital Affiliated to Medical School of Ningbo University, Ningbo 315040, China  
TONG Hong-zhang Yinzhou Hospital Affiliated to Medical School of Ningbo University, Ningbo 315040, China  
XU Lie-fu 南京医科大学附属常州二院放射科  
WANG Jian-hua 宁波大学附属医院放射科  
Hits: 2616
Download times: 2034
Abstract::
      Objective To explore the accuracy and radiation dose of the right ventricular analysis with DSCT(dual-source computed tomography)using dual-step prospective ECG trigger. Methods Forty-eight consecutive patients who were suspected or diagnosed with coronary artery disease were examined with DSCT coronary angiography and MRI ventricular analysis. Sequential acquisition and dual-step prospective ECG-trigger were used with 30%-90% width R-R interval. Full tube current output was adopted at 70% (HR≤70 bpm )or 40%(HR> 70 bpm) R-R interval according to heart rates,while 20% current output was adopted in other R-R interval. Coronary artery was divided into 16 segments according to the American Heart Association.Image quality of coronary arteries were graded with 4-points scale. The DSCT date was reconstructed with 5% R-R interval. RVESV, RVEDV and RVEF were evaluated in DSCT and MRI. Results Forty-two cases accomplished DSCT and MRI examination. In 558 evaluated coronary segments, 96.42% could be diagnosed. The average radiation dose was(2.82±0.55)mSv. Paired t-test indicated that the RVESV, RVEDV and RVEF of DSCT and MRI had no statistically significant differences(t=-0.28, 0.44 and 1.49,P>0.05), and the correlation was high (r=0.89, 0.89, 0.87). Conclusions The two generation DSCT with dual-step prospective ECG-triggered sequential acquisition can be used in coronary angiography and right ventricular function analysis simultaneously,which is high in imaging quality of coronary artery, reliable in right ventricular function analysis,as well as lower in radiation dose.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9074948  On-line:0

v
Scan QR Code
&et=93F632ED6E2662A6FCE07206EF7DDEE35DFF80DA82F4AADC3DB9ED31BF07ED34A12FA5A6B634DB11466FBCBA15077A794F2083F5121207FEF4FD2FCDE8EC369FCC6CDF3EA4BEC926BA8736CBF7A170DCC6754BACA3C78C82E124692EA1B573B60A9E946ECBF684BEB05C8DBC273D890C&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FF7AA908D58E97FA&aid=CBE5FA4F89B07936C1B7E32097EA437E&vid=&iid=E158A972A605785F&sid=BEE722AB5028E81F&eid=5319469C819FCFF1&fileno=20130430&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FF7AA908D58E97FA"; var my_aid="CBE5FA4F89B07936C1B7E32097EA437E";