ZHOU Shu-qin,CHEN Yi-ming,LI Shu-rong,PENG Zhen-peng,GAO Ying,YAN Chao-gui,ZHOU Xu-hui.The clinical research of low dose scanning protocol for aorto-iliac and lower extremity arteries CT angiography[J].Chinese Journal of Radiological Medicine and Protection,2013,33(3):318-322
The clinical research of low dose scanning protocol for aorto-iliac and lower extremity arteries CT angiography
Received:October 30, 2012  
DOI:10.3760/cma.j.issn.0254-5098.2013.03.025
KeyWords:MSCT  Lower extremity artery  Angiography  Low radiation dose
FundProject:广东省自然科学基金(8151008901000210)
Author NameAffiliationE-mail
ZHOU Shu-qin Guangdong Provical Hospital of TCM, Guangzhou 510020, China  
CHEN Yi-ming Guangdong Provical Hospital of TCM, Guangzhou 510020, China  
LI Shu-rong 中山大学附属第一医院放射科  
PENG Zhen-peng 中山大学附属第一医院放射科  
GAO Ying 中山大学附属第一医院放射科  
YAN Chao-gui 中山大学附属第一医院放射科  
ZHOU Xu-hui 中山大学附属第一医院放射科 xiaolintongqq@126.com 
Hits: 3679
Download times: 2230
Abstract::
      Objective To study the feasibility of reducing radiation dose in aorto-iliac and lower extremity arteries CT angiography(CTA) with low tube voltage (100 kV) and automatic tube current modulation(ATCM).Methods Totally 61 patients requiring aorto-iliac and lower extremity arteries CTA for clinical reasons were prospectively enrolled in study. The patients were randomly assigned to 3 groups: Group A(120 kV), Group B(100 kV) and Group C(100 kV with automatic tube current modulation). Both quantitative and qualitative analysis were included in this research. Group C was divided into obese group(BMI≥24.9 kg/m2)and normal group(BMI<24.9 kg/m2). The radiation doses were analyzed respectively among two groups. Results The subjective evaluations of image quality for axial, MIP and VR were good. There were no significant differences among group A, B and C in SNR and CNR(P>0.05). The effective dose of group A, B and C was 8.20 mSv, 5.36 mSv, and was 7.48 mSv, respectively Group B was 34.6% less than group A. Group C was 39.5% more than group B, and there was no significant differences between group A and C(P>0.05). The effective dose of group C1 was 7.11 mSv, group C2 was 9.69 mSv, the E with group C1 were significantly less than group C2(t=-3.163,P<0.05), the effective dose of group C1 was 13.3% less than group A(Z=-2.822,P<0.05), but the group C2 was more than group A(P>0.05) and group B(Z=-3.426,P<0.05). Conclusions Low-kilovoltage (100 kV) CT scanning protocol is feasible in multi-detector CT angiography for aortoiliac and lower extremity arteries. Automatic low tube voltage (100 kV) with automatic tube current modulation (ATCM) scanning protocol can be used for someone with BMI less than 24.9 kg/m2.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9079629  On-line:0

v
Scan QR Code
&et=379208D43D063767F7151EA5BEBA784F37FC8C4953A73C7F10E07BE46B3A3A222A4BEE6CCC5080AEF57DCB661A7A549EB43CC905C9D9EF99C97E77AB483F3FA88244AECD70045C797D57932D70BDAF77B6C5D88FFF3F227E8E96CEC3B4E293E2E0E8BB6A6A3E27499397798CC4090ACC&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FF7AA908D58E97FA&aid=A5FCAEE815B1622A4580F99DF3AB4BC3&vid=&iid=38B194292C032A66&sid=3C6F5C97A07587AE&eid=3224764AEAFCF8C2&fileno=20130325&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FF7AA908D58E97FA"; var my_aid="A5FCAEE815B1622A4580F99DF3AB4BC3";