Set-up error of CR in total body irradiation localization and lung shielding
Received:November 27, 2012  
DOI:10.3760/cma.j.issn.0254-5098.2013.03.021
KeyWords:Computed radiography  Total body irradiation  Image quality  Set-up error
FundProject:
Author NameAffiliationE-mail
HAN Jun Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430023, China  
LI Qin Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430023, China lq20092wh@yahoo.com.cn 
CAO Ting Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430023, China  
YANG Zhi-yong Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430023, China  
LIANG Zhi-wen Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430023, China  
CHEN Mi Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430023, China  
WEI Li-li Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430023, China  
Hits: 4194
Download times: 2774
Abstract::
      Objective To investigate the set-up error of CR in total body irradiation localization and lung shielding.Methods TOR 18FG software was employed to measure the image quality of images at kV and MV levels. The clinical processes were established and the positioning error was analyzed. Results The low contrast resolution and spatial resolution of MV level images were much worse than those at kV level in the condition of total body irradiation, but the image at MV level could be used to identify the high contrast tissues and employed in total body irradiation. The longitudinal errors were (0.50±1.65)cm for left lung and (1.16±1.56)cm for right lung in AP direction, while (1.12±2.22)cm and (0.41±2.16)cm respectively in PA direction. The errors of lateral were (0.81±1.19)cm for left lung and (0.43±1.20)cm for right lung in AP direction, while (0.31±1.64)cm and (0.55±1.49)cm respectively in PA direction.Conclusions Application of CR in total body irradiation could make positioning in treatment much easily and reduce the localization errors.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12026123  On-line:0

v
Scan QR Code
&et=8A2E07229E65C7D24C079FE78A182C349F49EC5F78FD36ECFFA4211F810560DB04B04C3FA9758046CBA26DA7897156B1948EEE58B77929557F116CC353316C4220C7731EFF1511A9D3D5D3E4EB417F71&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FF7AA908D58E97FA&aid=7E8ED74927464FD670397095D3D98A7F&vid=&iid=38B194292C032A66&sid=358F98408588E522&eid=407C905D8F0449C4&fileno=20130321&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FF7AA908D58E97FA"; var my_aid="7E8ED74927464FD670397095D3D98A7F";