ZHAO Rui,CHEN Jun-jun,LU Jun,LI Sha,WANG Zhen-yue,GAO Xing-xin.A study of the protection against induced radioactivity from Varian Clinac 21EX accelerator[J].Chinese Journal of Radiological Medicine and Protection,2013,33(2):191-193
A study of the protection against induced radioactivity from Varian Clinac 21EX accelerator
Received:May 22, 2012  
DOI:10.3760/cma.j.issn.0254-5098.2013.02.021
KeyWords:Accelerator  Induced radioactivity  Radiation protection
FundProject:
Author NameAffiliation
ZHAO Rui Department of Radiation Oncology, Lanzhou General Hospital, PLA, Lanzhou 730050, China 
CHEN Jun-jun 兰州军区放射卫生防护监测中心 
LU Jun 730050 兰州军区兰州总医院 
LI Sha 730050 兰州军区兰州总医院 
WANG Zhen-yue 730050 兰州军区兰州总医院 
GAO Xing-xin 730050 兰州军区兰州总医院 
Hits: 3366
Download times: 2326
Abstract::
      Objective To measure and analyze Varian Clinac 21EX accelerator induced radioactivity,and to provide specific recommendations and ways of radiation protection for radiotherapy technicians. Methods To simulate the working environment of radiotherapy technician, and to detect induced radioactivity variation of Varian Clinac 21EX accelerator that induced by 15 MV X-rays under different conditions of beam field area, dose, time, distance and by high energy electron beam (12,16,20 MeV) at the different time. Results The induced radioactivity level was not influenced by different beam field area, and was increased with increasing dose(r=0.930, P<0.05), decreased with time increase(r=-0.84, P<0.05), decreased with distance increase(r=-0.975, P<0.05). The induced radioactivity attenuation levels of the different doses at the same time are different, and have the common characteristic that the induced radioactivity attenuation rate is faster in the initial times. The induced radioactivity levels of high energy electron beams were significantly lower than those of high-energy X-rays. Conclusions During radiotherapy positioning, it is necessary to take measures to protect against the induced radioactivity when high-energy rays with energy greater than 10 MeV will be used. The radiotherapy technician should take the different time and energy interval steps for the different ray type and energy and dose in order to meet the radiation protection principle of optimization.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9056810  On-line:0

v
Scan QR Code
&et=2E8E91ED88C2FEB79312F605306536A71157A0FA8275A7526C3FA614EC771E55F2BB367E53EA221DBC8388C302D511FD344C9DD464E30044BC65273DEFA0ADA21F581974E8A5F92A65AE88B5454C47483A1095FF0C2D4771502DE87D71E914B1&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FF7AA908D58E97FA&aid=7B2D9635C2812955DFAFF9BDC9E46CC4&vid=&iid=0B39A22176CE99FB&sid=AC1578C6BB9EBDEF&eid=23104246A5FCFCEF&fileno=20130221&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FF7AA908D58E97FA"; var my_aid="7B2D9635C2812955DFAFF9BDC9E46CC4";