ZHANG Meng-long,DUAN Yu-ting,XU Yu-jun,LAN Di,ZHANG Liang-an.Optimization of radiological protection of patients undergoing digital radiography[J].Chinese Journal of Radiological Medicine and Protection,2013,33(2):183-186
Optimization of radiological protection of patients undergoing digital radiography
Received:June 03, 2012  
DOI:10.3760/cma.j.issn.0254-5098.2013.02.019
KeyWords:Optimization  Digital radiography  Radiation dose  Quality control  Exposure index
FundProject:
Author NameAffiliation
ZHANG Meng-long Shandong Medical Imaging Research Institute, Jinan 250021, China 
DUAN Yu-ting 聊城市人民医院 
XU Yu-jun 250021 济南,山东省医学影像学研究所 
LAN Di 青岛市立医院 
ZHANG Liang-an 中国医学科学院放射医学研究所 
Hits: 3154
Download times: 2469
Abstract::
      Objective To identify the necessity to carry out optimization procedure in routine digital radiography (DR) by evaluating changes of patient radiation dose and image waste ratio before and after optimization. Methods Two hundred patients with near-standard body build were enrolled in the study. Half of them undertook routine examination, and the others undertook the examination with bestly-optimized protocol. The dose-area product (DAP) and entrance surface dose (ESD) were recorded. The image waste ratios in 2 groups were calculated and the reasons for image waste were analyzed. The radiation dose and image waste ratio before and after optimization were compared. Results The ESD, DAP and image waste ratio in bestly-optimized radiography were significantly lower than those in non-optimized radiography (z=9.31, 16.22, P<0.05; χ2=36.5, P < 0.05). Conclusion Using the bestly-optimized digital radiography, the patient radiation dose and image waste ratio are effectively reduced.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9058806  On-line:0

v
Scan QR Code
&et=6AFDD1AF7FA60F03A94BFACA0D966912CE5FC1B92EE63450D1CEBD87EF5F6FC58BBC88D136BD3B7299B4FA928BCE7027B2624FF074460F5126F972DB587BBEFBC4943703BAA459C0DEF71E6D72B875DE4653803CB6DCD8E3&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FF7AA908D58E97FA&aid=7C87CE4EE0830EB69DDDE7049CA6AF6A&vid=&iid=0B39A22176CE99FB&sid=DD74772618543076&eid=50BBDFAC8381694B&fileno=20130219&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FF7AA908D58E97FA"; var my_aid="7C87CE4EE0830EB69DDDE7049CA6AF6A";