SUN Song-wei,ZOU Yue,LIU Jia-zhao,CHEN Xing-yu,WANG Cheng,LI Xiao.A dosimetric comparison of three-dimensional conformal and intensity-modulated radiotherapy in locally advanced pancreatic cancer and a study of the clinical efficacy[J].Chinese Journal of Radiological Medicine and Protection,2013,33(2):151-154
A dosimetric comparison of three-dimensional conformal and intensity-modulated radiotherapy in locally advanced pancreatic cancer and a study of the clinical efficacy
Received:November 16, 2012  
DOI:10.3760/cma.j.issn.0254-5098.2013.02.010
KeyWords:Locally advanced pancreatic cancer  IMRT  3D-CRT  Dosimetry  Regional chemotherapy
FundProject:
Author NameAffiliationE-mail
SUN Song-wei Second Artillery General Hospital,Beijing 100088,China  
ZOU Yue 100088 北京,解放军第二炮兵总医院 zyzy4145@163.com 
LIU Jia-zhao 宁夏医科大学  
CHEN Xing-yu 100088 北京,解放军第二炮兵总医院  
WANG Cheng 100088 北京,解放军第二炮兵总医院  
LI Xiao 100088 北京,解放军第二炮兵总医院  
Hits: 2827
Download times: 2498
Abstract::
      Objective To compare the dose distribution between three-dimensional conformal radiotherapy(3D-CRT) and intensity-modulated radiotherapy (IMRT) in treating locally advanced pancreatic cancer, and report the efficacy of IMRT combined with regional chemotherapy using gemcitabine (GEM). Methods Ten patients with locally advanced pancreatic cancer were enrolled in this study.3D-CRT and IMRT plans were designed for each patient. The dose distributions of target volume and normal tissues were analyzed using the dose volume histogram (DVH). Twenty-five locally advanced pancreatic cancers patients who were treated by IMRT combined with regional chemotherapy using gemcitabine(combined group) were retrospective analyzed, as well as 25 hospitalized patients of the same period who were treated by regional chemotherapy using gemcitabine alone (chemotherapy alone group).The therapeutic efficacy and adverse events were compared between two groups. Results IMRT plans decrease the mean dose and volume of duodenum, liver, stomach, both kidney and small bowel that received high-dose irradiation. The 1-,2-year survival rate of the combined group and chemotherapy alone group was 60%,28% and 36%,12%. The median survival time of two groups was 15 and 10 months,respectively(χ2=4.16,P<0.05). The total response rate of the combined group and the chemotherapy alone group was 64%and 32%,respectively(χ2=5.13,P<0.05).The upper gastrointestinal side-effect rate of the combined group was higher than that of the chemotherapy alone group(Z=-2.354,P<0.05).There was no statistic significance in hematologic toxicity, liver and renal functional damage between the two groups. Conclusions Compared with 3D-CRT plan, IMRT plan could reduce the dose of organ at risks. IMRT combined with regional chemotherapy using gemcitabine could significantly improve the survival rate of patients with locally advanced pancreatic cancer with mild adverse events.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9060258  On-line:0

v
Scan QR Code
&et=0C253F34206287688BE566376FCE76066CEC14DE0365554CE4EEE7E6307A7BEC1DD9979CECAD722658A99B174309B8E4C92A783920A171660EC2ADFF40160F5B4602DF2BEB5E8E6AEFD97CF7406865F71A9B53F8256E2F247D797A621628DBA42FE96EEA4524A3671565F2EDF9989B4ACC27DC0718494FB14F23F380F0664BB195B06804AA3DC9FF567E670405BBB0E97A752A7338A318E80112E4E3232E6CAA3ED9CD632AB79056&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=FF7AA908D58E97FA&aid=DC5D43B943A4CAC68056B76F4EC8F558&vid=&iid=0B39A22176CE99FB&sid=70AC2EF7F2065E09&eid=E2546871E5B846EF&fileno=20130210&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="FF7AA908D58E97FA"; var my_aid="DC5D43B943A4CAC68056B76F4EC8F558";