PAN Yu-ning,HUANG Qiu-li,REN Da-wei,WU An-le,YE Xian-wang,ZHANG Jie,CHEN Xiao-min,WANG Jian.Application value of low radiation dose coronary angiography using 320-slice volume CT[J].Chinese Journal of Radiological Medicine and Protection,2012,32(4):420-424,435
Application value of low radiation dose coronary angiography using 320-slice volume CT
Received:December 19, 2011  
DOI:10.3760/cma.j.issn.0254-5098.2012.04.025
KeyWords:320-slice volume CT  Coronary angiography  Noise  Radiation dose
FundProject:宁波市社会发展科研项目(2011C50075)
Author NameAffiliationE-mail
PAN Yu-ning Department of Radiology, Ningbo First Hospital, Ningbo 315010, China  
HUANG Qiu-li Department of Radiology, Ningbo First Hospital, Ningbo 315010, China huang_qiuli@126.com 
REN Da-wei Department of Radiology, Ningbo First Hospital, Ningbo 315010, China  
WU An-le Department of Radiology, Ningbo First Hospital, Ningbo 315010, China  
YE Xian-wang Department of Radiology, Ningbo First Hospital, Ningbo 315010, China  
ZHANG Jie Department of Radiology, Ningbo First Hospital, Ningbo 315010, China  
CHEN Xiao-min 315010 宁波市第一医院心内科  
WANG Jian 315010 宁波市第一医院心内科  
Hits: 3703
Download times: 2112
Abstract::
      Objective To evaluate the image quality and radiation dose of prospective electrocardiography-triggered coronary 320-slice volume CT angiography with different kV, and the feasibility of coronary scan with <1 mSv radiation dose.Methods Eighty consecutive patients were randomly divided into two groups equally.The tube voltage according to paradigm was 100 kV in group A and 120 kV in group B. All raw data in group A was reconstructed by the software AIDR in CT system to create a new group named as A1. Such parameters as the mean intraluminal attenuation (SI), noise (SD), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR),effective radiation dose(E) and image quality score measured in group A were compared with those in group B. The values such as SI, SD, SNR, CNR, image quality scores were compared between group A and group A1. The significance of group B and group A1 was compared in SI, SD, SNR, CNR, image quality scores as well. Results E in group A was significantly lower than that in group B[E=(0.67 ± 0.18) mSv in group A vs. E=(3.08 ± 1.04) mSv in group B]. The value of E in group A was decreased by 78% compared to group B(t=-14.30, P<0.05). There was no significant difference in mean image quality scores between two groups(4.57 ± 0.57 in group A vs. 4.59 ± 0.59 in group B, t=-1.17, P>0.05). The values of SI, SD, SNR, CNR in group A were (570.8±131.5)HU, 25.1±6.9, 24.5±9.1, 19.8±6.1. And the values of SI, SD, SNR, CNR in group B were (460.6 ± 14.3) HU, 15.1±3.6, 31.7±7.7, 29.3±6.8. The values of SI and SD in group A were significantly higher than those in group B(t=4.49,8.18, P<0.05). The values of SNR and CNR in group A were lower than those in group B (t=-4.24,-6.19, P<0.05). The values of SI,SD, SNR, CNR,image quality scores in group A1 were (557.9±24.5) HU, 21.1±6.0, 27.7±10.0, 23.4±7.8, 4.60 ± 0.56. There was no difference in the SI and the image quality scores between group A and group A1 (t=1.09,-1.90, P>0.05). Conclusions 320-slice volume CT with 100 kV tube voltage and prospective ECG-triggered technique can reduce the radiation dose to less than 1 mSv and obtain optimal images in diagnosis of coronary arterial diseases.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9061511  On-line:0

v
Scan QR Code
&et=DCA5CABA83612A94F0F16D09AE51DD0EA667CD77BC03BA5FC6C48A1B0180FF83FCA616325FAAC037446E267BFB7F8EA44C0C82C88FAFFEFE324B5E0C922685DACD8A6B73F7050278FCA14C371BF42E555501EDF3CF18D806&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=99E9153A83D4CB11&aid=9B3C227A81E2A28C1AF7243A46E326E8&vid=&iid=E158A972A605785F&sid=5335AD3CFE6E14EA&eid=44D2D170946923BE&fileno=20120425&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="99E9153A83D4CB11"; var my_aid="9B3C227A81E2A28C1AF7243A46E326E8";