WANG Zhi-kang,SUN Jian-zhong,ZHAO Zu-dan.Cumulative radiation dose of multiple trauma patients during their hospitalization[J].Chinese Journal of Radiological Medicine and Protection,2012,32(3):323-325
Cumulative radiation dose of multiple trauma patients during their hospitalization
Received:January 05, 2012  
DOI:10.3760/cma.j.issn.0254-5098.2012.03.026
KeyWords:Cumulative effective doses  Multiple trauma  X-ray
FundProject:浙江省科学技术厅2010年度省级公益性技术应用研究项目(2010C33064)
Author NameAffiliationE-mail
WANG Zhi-kang Department of Clinical Engineering, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China  
SUN Jian-zhong 310009 杭州, 浙江大学医学院附属二院放射科 hzzjsjz@yahoo.com.cn 
ZHAO Zu-dan 310009 杭州, 浙江大学医学院附属二院放射科  
Hits: 3220
Download times: 2374
Abstract::
      Objective To study the cumulative radiation dose of multiple trauma patients during their hospitalization and to analyze the dose influece factors.Methods The DLP for CT and DR were retrospectively collected from the patients during June, 2009 and April, 2011 at a university affiliated hospital.The cumulative radiation doses were calculated by summing typical effective doses of the anatomic regions scanned.Results The cumulative radiation doses of 113 patients were collected. The maximum, minimum and the mean values of cumulative effective doses were 153.3,16.48 mSv and(52.3±26.6)mSv.Conclusions Multiple trauma patients have high cumulative radiation exposure. Therefore, the management of cumulative radiation doses should be enhanced. To establish the individualized radiation exposure archives will be helpful for the clinicians and technicians to make decision wheather to image again and how to select the imaging parameters.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9074396  On-line:0

v
Scan QR Code
&et=E2AC72EFAE71070B547AC5EF082321E10BC7F6C72773DA2411282064072EDBC3E93373426BB3450CC0DA327DBFB7F36CB5A99612FFDF8663F7D0373E5F49E97EC2675B02E722B9D94B9BF3632F3233AC2DC294E5D46BD9F4&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=99E9153A83D4CB11&aid=669A8D56CCC2B6A189B2192A4D395AE5&vid=&iid=38B194292C032A66&sid=892C6E385D640C1E&eid=86C0C9A759FDA8CA&fileno=20120326&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="99E9153A83D4CB11"; var my_aid="669A8D56CCC2B6A189B2192A4D395AE5";