GONG Guan-zhong,YIN Yong,LIU Tong-hai,CHEN Jin-hu,SONG Jin-long,LU Jie,MA Chang-sheng,SUN Tao,BAI Tong.Dosimetric differences among RapidArc plans based on different target volumes in radiotherapy of hepatocelluar carcinoma[J].Chinese Journal of Radiological Medicine and Protection,2012,32(3):289-293
Dosimetric differences among RapidArc plans based on different target volumes in radiotherapy of hepatocelluar carcinoma
Received:July 13, 2011  
DOI:10.3760/cma.j.issn.0254-5098.2012.03.017
KeyWords:Hepatocelluar carcinoma  Radiotherapy  Intensity-modulated arc radiotherapy  Dosimetry
FundProject:山东省自然科学基金(ZR2010HM071)
Author NameAffiliationE-mail
GONG Guan-zhong Department of Radiation Oncology, Shandong Cancer Hospital, Shandong Provincial Key Laboratory of Radiation Oncology, Shandong Academy of Medical Sciences, Jinan 250117, China  
YIN Yong Department of Radiation Oncology, Shandong Cancer Hospital, Shandong Provincial Key Laboratory of Radiation Oncology, Shandong Academy of Medical Sciences, Jinan 250117, China yinyongsd@yahoo.com.cn 
LIU Tong-hai Department of Radiation Oncology, Shandong Cancer Hospital, Shandong Provincial Key Laboratory of Radiation Oncology, Shandong Academy of Medical Sciences, Jinan 250117, China  
CHEN Jin-hu Department of Radiation Oncology, Shandong Cancer Hospital, Shandong Provincial Key Laboratory of Radiation Oncology, Shandong Academy of Medical Sciences, Jinan 250117, China  
SONG Jin-long Department of Radiation Oncology, Shandong Cancer Hospital, Shandong Provincial Key Laboratory of Radiation Oncology, Shandong Academy of Medical Sciences, Jinan 250117, China  
LU Jie Department of Radiation Oncology, Shandong Cancer Hospital, Shandong Provincial Key Laboratory of Radiation Oncology, Shandong Academy of Medical Sciences, Jinan 250117, China  
MA Chang-sheng Department of Radiation Oncology, Shandong Cancer Hospital, Shandong Provincial Key Laboratory of Radiation Oncology, Shandong Academy of Medical Sciences, Jinan 250117, China  
SUN Tao Department of Radiation Oncology, Shandong Cancer Hospital, Shandong Provincial Key Laboratory of Radiation Oncology, Shandong Academy of Medical Sciences, Jinan 250117, China  
BAI Tong Department of Radiation Oncology, Shandong Cancer Hospital, Shandong Provincial Key Laboratory of Radiation Oncology, Shandong Academy of Medical Sciences, Jinan 250117, China  
Hits: 4305
Download times: 2205
Abstract::
      Purpose To investigate the dosimetric differences among RapidArc (RA) plans which were designed on different target volumes in hepatocellular carcinoma (HCC).Methods A total of 10 HCC patients underwent 3D-CT scan under free breathing (FB), end inspiration hold (EIH) associated with active breath coordinator (ABC) and 4D-CT scan. The 4D-CT were sorted into 10 sets of CT images according to respiratory cycle. The gross tumor volume (GTV) was manually contoured on different CT images. The individual internal gross target volume (IGTV1) was obtained from 4D-CT, and the individual margins from GTVFB to IGTV1. IGTV2 were obtained from GTVFB using individual margins. The planned target volumes (PTV-1, PTV-2, PTV-3 and PTV-4) were obtained from GTVFB, IGTV1, IGTV2 and GTVEIH applying different margins. The RA plans (RA1, RA2, RA3 and RA4) were designed from different PTVs, and for RA1, RA2 and RA3 the simple 358° arc were used,while three 135° arcs were used for RA4.The dosimetric differences were compared. Results The PTV-1 and PTV-3 were larger than PTV-2 and PTV-4; the mean values of PTV-1/PTV-2 and PTV-1/PTV-4 were 2.5 and 1.9, respectively. There were no significant differences in conformal index, homogeneity index, maximum dose, and minimum dose of PTV among 4 RA plans. The irradiation dose of normal liver of RA3 and RA4 were 8.23 Gy and 7.63 Gy respectively, both significantly lower than those of RA1 and RA2 (10.21 Gy, 9.62 Gy, χ2=10.68, P<0.05), and the V30 of RA3 and RA4 were 5.24% and 5.05% respectively, both significantly lower than those of RA1 and RA2 (7.76%, 6.12%, χ2=14.76, P<0.05). There were no significant differences in irradiation doses of stomach and duodenum among different plans.Conclusions Using 4D-CT or ABC technology with RapidArc in HCC can define the target volume accurately and achieve prefect dose distribution sparing more normal liver volume, compared to the traditional margins. 4D-CT and ABC play similar roles in sparing normal liver.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9076905  On-line:0

v
Scan QR Code
&et=8400690B225D0A44F57DFFF6EE1F992BBC33D645DCBEE0E80AF95A159BB6256C34D62C4724C5539F5237F46375302578050C112448E3DA8073A7098DCCB2E0E617FB0EE4F7024847EB06CADE13566D6D3B6422E1000523B0A3ED5910D835526F29ACD8DB7CF8002AA556907B2F91EBDE74F5B8933D6461C1F0BAA06C165C9BC4&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=99E9153A83D4CB11&aid=669A8D56CCC2B6A139F922412E234AC2&vid=&iid=38B194292C032A66&sid=F50A8B5513721E1C&eid=2AC7DCCBBC26ECF8&fileno=20120317&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="99E9153A83D4CB11"; var my_aid="669A8D56CCC2B6A139F922412E234AC2";