LUO Qing-bin,CHEN Xiao-hua,DONG Bo,et al.Influence of whole-body irradiation with low-dose γ-rays on amino acid neurotransmitter levels in mice brain tissue[J].Chinese Journal of Radiological Medicine and Protection,2012,32(2):179-181
Influence of whole-body irradiation with low-dose γ-rays on amino acid neurotransmitter levels in mice brain tissue
Received:October 30, 2011  
DOI:10.3760/cma.j.issn.0254-5098.2012.02.018
KeyWords:γ-rays|Mice|Low-dose irradiation|Neurotransmitters
FundProject:
Author NameAffiliationE-mail
LUO Qing-bin 215123 苏州大学临床医学院  
CHEN Xiao-hua Clinical Medical College, Soochow University, Suzhou 215123, China chenxh0676@sina.com.cn 
DONG Bo 军事医学科学院放射与辐射医学研究所  
JIANG He-zuo 第二炮兵总医院肿瘤科  
LI Feng-sheng 第二炮兵总医院中心实验室  
LI Bo 第二炮兵总医院肿瘤科  
Hits: 4701
Download times: 3347
Abstract::
      Objective To investigate the effect of whole-body irradiation with low-dose γ-rays on the central nervous system of mice. Methods Fifty C57 mice were randomly divided into 3 groups and treated with 0, 0.5, 1 Gy whole-body irradiation, respectively. 24 or 48 h after irradiation, brain tissue of mice was resected and homogenated. The levels of amino acid neurotransmitter, including Glu, Asp, GABA and Gly in brain homogenate were measured by high performance liquid chromatography (HPLC). Results Compared to the brain tissue of untreated mice, the contents of Glu and Asp at 0.5 and 1 Gy (t=-4.080,-3.935,-4.416,-3.630,-4.831, -4.656,P<0.05) in mice brain tissue significantly increased at 24 h at 1 Gy and 48 h. However, the contents of Glu and Asp had no obvious changes in mice brain tissue 24 h after 1 Gy of irradiation. The contents of GABA and Gly had no difference between irradiated groups and untreated control group. Conclusions Short-term whole-body irradiation with low-dose γ-rays induces slight stimulation effect on the central nervous system of mice.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11565397  On-line:0

v
Scan QR Code
&et=22F1D5E3CC41362BFB01CBF0F87E0736E3D7CF11965A8D8127B95D1603306930376E650A9A3B73F10B222CE4DA0FF8BD390B6BCF9236C5979589776AF31DBB83090DB59587ACF8A3ED8C6E17C3269D052F9472C21B29FCE1DFC4246720A7EF2E493B2C37577D837AC4E8BDDF9D72A78A89C451E38DBBC691&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=99E9153A83D4CB11&aid=C55425D73451440EA62B38B5237773AF&vid=&iid=0B39A22176CE99FB&sid=E114CF9BB47B65BE&eid=7EBE588F611589FC&fileno=20120218&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="99E9153A83D4CB11"; var my_aid="C55425D73451440EA62B38B5237773AF";