SONG Tie-li,ZHENG Lei,HUANG Ming-wei,ZHANG Jie,ZHANG Hong-zhi,ZHANG Jian-guo.Target volume determination of postoperative 125I seeds interstitial brachytherapy in parotid gland carcinoma[J].Chinese Journal of Radiological Medicine and Protection,2011,31(5):564-566
Target volume determination of postoperative 125I seeds interstitial brachytherapy in parotid gland carcinoma
Received:November 28, 2009  
DOI:10.3760/cma.j.issn.0254-5098.2011.05.015
KeyWords:125I seeds  Interstitial brachytherapy  Target volume  Parotid region
FundProject:首都医学科研发展基金(2005-2006)
Author NameAffiliation
SONG Tie-li *Peking University School and Hospital of Stomatology, Beijing 100081, China 
ZHENG Lei 100081 北京大学口腔医院口腔颌面外科 
HUANG Ming-wei 100081 北京大学口腔医院口腔颌面外科 
ZHANG Jie 100081 北京大学口腔医院口腔颌面外科 
ZHANG Hong-zhi 中国医学科学院肿瘤医院放射治疗科 
ZHANG Jian-guo 100081 北京大学口腔医院口腔颌面外科 
Hits: 3901
Download times: 2149
Abstract::
      Objective To explore the method of target volume determination of postoperative 125I seeds interstitial brachytherapy in parotid gland carcinoma. Methods A total of 31 cases(14 males and 17 famales) with primary parotid carcinoma who were treated in Peking University Hospital of Stomatology from Oct 2002 to Nov 2006. The patients' average age was 38.2 years. All patients underwent tumor resection and postoperative 125I seeds interstitial brachytherapy with 60 Gy matched peripheral dose. The spiral CT was performed for treatment plan and quality verification before and after the brachytherapy. The bone and muscle landmarks surrounding parotid were selected as reference for target volume determination. D90 of target volume and dose of organs at risk were calculated, while the target volume and D90 of target volume of verification were compared with that of treatment plan through quality verification. Results The target volume or D90 of target volume before and after treatment was not statistically different. D90 of target volume was more than 60 Gy. During 3-7 years of follow-up, all patients had no recurrence. ConclusionsAccording to the follow-up results, the method used for target volume determination in this paper might be satisfied.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9057827  On-line:0

v
Scan QR Code
&et=B10861F71200F83539F6022069DC45895658F6B01E0188FBECE6B51A904DEB271A545EE6A4621C4A7B9A3D79F597EBB78B5950E3D2F9F35390F6E674904F46128341B04655B443D8C0AAAE2D1495E926D55486E7BA2BE86A131095CC306D98C078A6866B60AFC2CE788E4B7377951C7EFDBE526DC6ACDB0185593772EA041268&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9377ED8094509821&aid=3897C9445ED3113A7AC2F1D707196A39&vid=&iid=94C357A881DFC066&sid=2497388423811B81&eid=CDC418F38C4BFD60&fileno=20110515&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9377ED8094509821"; var my_aid="3897C9445ED3113A7AC2F1D707196A39";