ZHANG Yi,SONG Shao-juan,QU Gui-lian,LIU Wei-dong,GUO Jian-jun.Radiation exposure to patients during 10 interventional radiology procedures[J].Chinese Journal of Radiological Medicine and Protection,2011,31(4):482-484
Radiation exposure to patients during 10 interventional radiology procedures
Received:December 23, 2010  
DOI:10.3760/cma.j.issn.0254-5098.2011.04.029
KeyWords:Interventional radiology  Radiation dose  Radiation protection
FundProject:
Author NameAffiliationE-mail
ZHANG Yi Shandong Medical Imaging Research Institute, Jinan 250021, China  
SONG Shao-juan Shandong Medical Imaging Research Institute, Jinan 250021, China songshj2003@163.com 
QU Gui-lian Shandong Medical Imaging Research Institute, Jinan 250021, China  
LIU Wei-dong Shandong Medical Imaging Research Institute, Jinan 250021, China  
GUO Jian-jun Shandong Medical Imaging Research Institute, Jinan 250021, China  
Hits: 3161
Download times: 2328
Abstract::
      Objective To investigate radiation dose to the patients undergoing interventional radiology and make radiation risk assessment. Methods Data was collected on 198 instances of 10 interventional radiology procedures by using Philips Allura Xper FD20 DSA, which was equipped with the transparent ionization chamber system in compliance with IEC 60601-2.Patient peak skin dose and effective dose were estimated. Results Cumulative fluoroscopy time was 2.1-80.9 min, and number of images was 15-678 frames, and DAP was 11-825 Gy·cm2, and CD was 24-3374 mGy. A total of 16 cases monitored for PSD were above 1 Gy and 79 cases monitored for E were above 20 mSv. Conclusions Substantial number of cases exceeded the dose threshold for erythema. Due attention should be paid to radiation protection of patients.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9072925  On-line:0

v
Scan QR Code
&et=15C444C2D45CD59A8ECBE96467EDA5019967F3A042CE264823400E88F93B320B61681118E660D01A45E709C1A2BDB6747DDD67A1D37412EF22C048249FA7E2859F98D44A8A9BB3A2890BA5FEC3CE73DD&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9377ED8094509821&aid=CF465D37670C8355F29B0A1BF283EC62&vid=&iid=E158A972A605785F&sid=BE5DBC360CD4FFB9&eid=D8B37A0210DB6B9D&fileno=20110429&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9377ED8094509821"; var my_aid="CF465D37670C8355F29B0A1BF283EC62";