XUE Xiu-jia,ZHANG You-jiu.A pre-treatment device designed for tritium analysis in biological samples[J].Chinese Journal of Radiological Medicine and Protection,2011,31(4):478-481
A pre-treatment device designed for tritium analysis in biological samples
Received:January 09, 2011  
DOI:10.3760/cma.j.issn.0254-5098.2011.04.028
KeyWords:Biological samples  Organically bound tritium  Combustion  Liquid scintillation counting(LSC)
FundProject:
Author NameAffiliationE-mail
XUE Xiu-jia School of Radiation Medicine and Public Health, Medical College of Soochow University, Suzhou 215123, China  
ZHANG You-jiu School of Radiation Medicine and Public Health, Medical College of Soochow University, Suzhou 215123, China yjzhang@suda.edu.cn 
Hits: 3580
Download times: 2545
Abstract::
      Objective To design a new pre-treatment device and to evaluate its efficiency in order to monitor the tritium levels in biological samples. Methods The detection efficiency of tritium was determined with standard tritiated water. Recovery of tritiated water and organically bound tritium (OBT) were detected with high, medium and low activities of standard tritiated water and 3H-TdR (tritiated thymidine), respectively. Comparison of three kinds of biological samples using different pre-treatment devices was shown. Results The standard curve can be used in environmental tritium measurement and the detection efficiency for tritium was 23.3%. When 40.0 g rice with standard HTO or 3H-TdR was pre-treated with this device, the average recovery of HTO and OBT was about 95.4%, which showed good reproducibility. The comparison results were similar. Conclusions The pre-treatment device can be used to survey the OBT in environmental biological samples.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9069435  On-line:0

v
Scan QR Code
&et=6955FB871E7FAA1406F846CD303C303292DD6F277679932F4710959A1ED03B33ACE5BCC4DE59891A4D72B29F4CB8A3FB9049F2B6BFDD8CFDE814208167BA939693A3D4F45301AE0271AD631E76509935&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9377ED8094509821&aid=CF465D37670C8355D84F87A0C51527C9&vid=&iid=E158A972A605785F&sid=A94616C4391AA5EF&eid=283B38DAD0D068F3&fileno=20110428&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9377ED8094509821"; var my_aid="CF465D37670C8355D84F87A0C51527C9";