ZHANG Lin,ZHU Jian-guo,MIN Nan,LU Feng,CHEN Yue.Estimation of the effective doses for interventional employees in three common interventional diagnosis and treatment procedures[J].Chinese Journal of Radiological Medicine and Protection,2011,31(4):391-394
Estimation of the effective doses for interventional employees in three common interventional diagnosis and treatment procedures
Received:January 17, 2011  
DOI:10.3760/cma.j.issn.0254-5098.2011.04.004
KeyWords:Interventional employees  Anthropomorphic phantom  Tissue weight factor  Effective dose
FundProject:国家科技支撑计划(2006BAI06B03)
Author NameAffiliationE-mail
ZHANG Lin Institute of Radiation Medicine, Shandong Academy of Medical Science, Jinan 250062, China  
ZHU Jian-guo Institute of Radiation Medicine, Shandong Academy of Medical Science, Jinan 250062, China sdfanghu@sohu.com 
MIN Nan Institute of Radiation Medicine, Shandong Academy of Medical Science, Jinan 250062, China  
LU Feng Institute of Radiation Medicine, Shandong Academy of Medical Science, Jinan 250062, China  
CHEN Yue Institute of Radiation Medicine, Shandong Academy of Medical Science, Jinan 250062, China  
Hits: 4443
Download times: 3135
Abstract::
      Objective To study and estimate the effective dose of interventional employees in the common cerebralvascular, cardiovascular and liver interventional diagnosis and treatment. Methods The absorbed doses of tissue or organ of anthropomorphic phantom in these three procedures were estimated by the anthropomorphic phantom experiment. The effective doses were calculated by the tissue weight factor which was given by International Commission on Radiological Protection publication 103. Results The effective doses to high, medium and low group were 24.0, 9.7,6.8 μSv for cerebralvascular interventional diagnosis and treatment, and 36.3, 29.3, 17.8 μSv for cardiovascular interventional diagnosis and treatment,and 23.9, 11.3, 5.5 μSv for liver interventional diagnosis and treatment, respectively. Conclusions The effective doses of high, medium and low group of interventional employees in cardiovascular interventional procedure are higher than those of cerebralvascular and liver interventional procedures.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9069766  On-line:0

v
Scan QR Code
&et=EC9A7F1C2771EE50D6E8B3422547DB6D9FFB5B1BF7C173825CE346A6309173FA6FC4111E3A0CABE349BD2FA101178885F2D8C9EEF0BA35387CA92272445E90B3EFA89059288DD1C017A208551229494A821EC710B9545C78C68E574AD197D9B3FE5AF81DF4D208CBC61B19F5C65E9086EF01DECF73D7CCFF7F8759B1C09EE7983E11AE8FE205049D&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9377ED8094509821&aid=CF465D37670C835523DC2235B3A18680&vid=&iid=E158A972A605785F&sid=AFB2C35009D5D191&eid=0BD4FAD4A90498AB&fileno=20110404&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9377ED8094509821"; var my_aid="CF465D37670C835523DC2235B3A18680";