LIU Li-bo,ZHANG Jian,LIU Yu-guang,NI Guan-ying,LIU Shu-zheng.Correlation analysis on MN-RET from peripheral blood and MN-PCE from bone marrow in mice following exposure to irradiation[J].Chinese Journal of Radiological Medicine and Protection,2011,31(2):122-125
Correlation analysis on MN-RET from peripheral blood and MN-PCE from bone marrow in mice following exposure to irradiation
Received:December 01, 2010  
DOI:10.3760/cma.j.issn.0254-5098.2011.02.002
KeyWords:Radiation  Mice  Reticulocyte micronucleus  Polychromatic erythrocyte micronucleus  Flow cytometry  Biodosimeter
FundProject:卫生行业科研专项(200802018)
Author NameAffiliation
LIU Li-bo School of Public Health, Jilin University, Changchun 130021,China 
ZHANG Jian School of Public Health, Jilin University, Changchun 130021,China 
LIU Yu-guang School of Public Health, Jilin University, Changchun 130021,China 
NI Guan-ying School of Public Health, Jilin University, Changchun 130021,China 
LIU Shu-zheng School of Public Health, Jilin University, Changchun 130021,China 
Hits: 5988
Download times: 2946
Abstract::
      Objective To study the changes of reticulocyte micronucleus(MN-RET) from peripheral blood and polychromatic erythrocyte micronucleus(MN-PCE) from bone marrow in mice following exposure to X-rays in order to provide an experimental basis for exploring possible high-throughput radiation biodosimeter. Methods Male ICR mice were whole-body irradiated with 0, 0.5, 1, 2, 4 and 5 Gy at a dose rate of 0.488 Gy/min. MN-RET from peripheral blood was scored with FCM and MN-PCE from bone marrow was scored with manual microscopy at 24, 48 and 72 h post-irradiation. Results Both MN-RET and MN-PCE rates increased with doses in the range of 0-5 Gy at 24, 48 and 72 h after WBI. The dose-response relationship can be fit with linear equations (t=10.26-25.77, P<0.05). The correlation coefficients between MN-RET from peripheral blood and MN-PCE from bone marrow were highly significant (r=0.986-0.996, P<0.05). Conclusions In view of its simplicity, accuracy and high-throughput capacity, FCM scoring of peripheral blood MN-RET may be a candidate for radiation biodosimetry. More work should be carried out on human specimens to investigate this possibility.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:9078757  On-line:0

v
Scan QR Code
&et=D67FB00049905872593C572417459E694A0CBA451AB8B94AA7303D205BCCC4D5482829745E2BC114450913A5C64E36FED6995D0A41F2C85316F1E97D6CE2C6D2CC3C80217648D93B5B22EF48EB9AF8896512DB43304AB9F8FF3C954A2C6FCE0D978E01CF91C790C22D40B6493620848AE060B757CE29B0EE0DBB51DCD87D8B25&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=9377ED8094509821&aid=44F006F75B33854688BCA5C946806932&vid=&iid=0B39A22176CE99FB&sid=B62E0EEFE746E568&eid=F122871CC7EC92DC&fileno=20110202&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="9377ED8094509821"; var my_aid="44F006F75B33854688BCA5C946806932";