SHEN Ge,WANG Fang,ZHANG Wei-jing,et al.Mesenchymal stem cells reduce the irradiation induced lung injury[J].Chinese Journal of Radiological Medicine and Protection,2010,30(6):670-673
Mesenchymal stem cells reduce the irradiation induced lung injury
Received:February 11, 2010  
DOI:
KeyWords:Irradiation induced lung injury  Mesenchymal stem cells  Mouse bone  Mouse embryos dorsal aorta area
FundProject:国家自然科学基金 (30972974)
Author NameAffiliationE-mail
SHEN Ge Department of Radiation Oncology, Affiliated Hospital to Academy of Military Medical Science, Beijing 100071, China  
WANG Fang 100071 北京, 军事医学科学院附属医院淋巴瘤内科  
ZHANG Wei-jing 100071 北京, 军事医学科学院附属医院淋巴瘤内科 zhangwj3072@163.com 
LIU Bing 100071 北京, 军事医学科学院附属医院肿瘤分子实验室  
YUAN Shun-zong 100071 北京, 军事医学科学院附属医院淋巴瘤内科  
WANG Li 100071 北京, 军事医学科学院附属医院淋巴瘤内科  
SHAO Yun 100071 北京, 军事医学科学院附属医院病理科  
Hits: 4474
Download times: 2761
Abstract::
      Objective To evaluate the role of mesenchymal stem cells (MSCs) derived from mouse bone and embryo dorsal aorta(DA)area in the treatment of irradiation induced lung injury of mouse model. Methods The mice were divided into four groups as normal control group, irradiation group, bone MSCs treatment group and DA MSCs treatment group. Immunohistochemical Analysis of lung tissue was observed after 9 months of treatment. Results Fibrosis and alveolar infiltration were scored in each group. The score for fibrosis and alveolar is 0.17 in normal control group, 2 in irradiation group, 1 in bone MSCs treat group and 1.38 in DA MSCs treat group. Conclusion The extent of irradiation Induced Lung Injury could be reduced thorough the treatment of MSCs derived from mouse bone and embryos dorsal aorta(DA)area.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11565398  On-line:0

v
Scan QR Code
&et=DF68FB1F9D12489923CB416316F803CD46960754790F942E84AA2D9ACE5988BAA81E0514C6082FC191E3A98D2F91EE1D2FF6F18F702E53F5BA7EC070002FEC565B5163B3214A4CDF&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=140ECF96957D60B2&aid=2374D734303E95E196CED79F58BAEA30&vid=&iid=B31275AF3241DB2D&sid=2B6C525BCE31A7DA&eid=B28C697BC3A1BA62&fileno=20100610&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="140ECF96957D60B2"; var my_aid="2374D734303E95E196CED79F58BAEA30";