LU Xue,ZHAO Hua,LIANG Li,et al.Retrospective dose estimation for individuals exposed to accidental exposure in uterus with fluorescence in situ hybridization[J].Chinese Journal of Radiological Medicine and Protection,2010,30(5):513-515
Retrospective dose estimation for individuals exposed to accidental exposure in uterus with fluorescence in situ hybridization
Received:January 06, 2010  
DOI:
KeyWords:Xinzhou radiation accident  In-uterus exposure  Retrospective dose estimation  Fluorescence in situ hybridization
FundProject:国家自然科学基金(30570551, 30870749);卫生行业科研专项(200802018)
Author NameAffiliationE-mail
LU Xue National Institute for Radiation Protection, Chinese Center for Disease Control and Prevention, Beijing 100088,China  
ZHAO Hua National Institute for Radiation Protection, Chinese Center for Disease Control and Prevention, Beijing 100088,China  
LIANG Li 北京大学第三医院  
ZHANG Shu-lan 北京大学第三医院  
FENG Jiang-bin National Institute for Radiation Protection, Chinese Center for Disease Control and Prevention, Beijing 100088,China  
ZHANG Zhao-hui 北京大学第三医院  
CHEN De-qing National Institute for Radiation Protection, Chinese Center for Disease Control and Prevention, Beijing 100088,China  
MA Li-wen 北京大学第三医院  
JIA Ting-zhen 北京大学第三医院  
LIU Qing-jie National Institute for Radiation Protection, Chinese Center for Disease Control and Prevention, Beijing 100088,China qjliu@nirp.cn 
Hits: 3184
Download times: 2470
Abstract::
      Objective To reconstruct the absorbed dose for the individual who was accidentally exposed in uterus 16 years ago. Methods Peripheral blood samples were taken from the victim and her mother. The dicentric and centric ring chromosome aberrations were analyzed with conventional method, the micronucleus was observed with cytokinesis-block micronucleus method, and fluorescence in situ hybridization (FISH) with chromosomes 1, 2 and 4 painting probes were used for translocation detection. Dose was estimated according to the standard dose-response curves previously established. Results No unstable chromosome aberrations and normal micronucleus frequencies were observed in two persons 16 years after the accident. Against the established dose-response curves with FISH, the doses to the mother and her daughter were 0.76 Gy (95% CI 0.41-1.00 Gy) and 0.61 Gy (95% CI 0.44-0.86 Gy), respectively. Because the biological dose estimated for the mother 1 month after the accident was 2.30 Gy (95% CI 2.07-2.50 Gy), the dose correction factor was 3.03 for dose estimation 16 years later. The estimated dose in uterus to the victim was 1.85 Gy (95% CI 1.33-2.61 Gy). Conclusions The estimated dose to the individual accidentally exposed in uterus 16 years ago can be obtained according to the dose correction factor of the mother with FISH method.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:11565709  On-line:0

v
Scan QR Code
&et=5AE0F80741DB75F8DE736E93BF92724E07193232DF1E3DC0A15B0691DD6BF22DE4AD8EE471F95BFEBF9A402DD254774476B9E79E6CE04F7FF334F7EC77EA1E94632680A7D25E27F9DEF181F205001C4A8385709288832B21C102B0661D45F96312ADD192D6CDEFD959E61BC31FD382A5663BA35CB197517F11F162DD8578F6CC6905638F283BAC1A&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=140ECF96957D60B2&aid=D333A82E1A5DD7532A5C358577E64B54&vid=&iid=94C357A881DFC066&sid=F9A6B6F259CE5121&eid=F204392B3B11C3BD&fileno=20100505&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="140ECF96957D60B2"; var my_aid="D333A82E1A5DD7532A5C358577E64B54";